Wiring Diagram - Keating Of Chicago 2000 Installation Manual

Gas griddle
Hide thumbs Also See for 2000:
Table of Contents

Advertisement

Pilot on but no main
burner ignition
Temperature of
griddle erratic
Griddle stays hot or
overheats
GAS GRIDDLE WIRING DIAGRAM
a. ON/OFF switch is in "OFF"
position.
b. Gas valve is in "pilot" position.
c. Thermostat is not turned on.
d. Low gas pressure.
e. Gas valve failure.
a. Thermostat is not calibrated.
b. Air from exhaust hood excessive.
a. Thermostat is not calibrated.
b. Thermostat failure.
c. Air from exhaust hood excessive.
a. Put ON/OFF switch to "ON" position.
b. Turn knob to "ON" position.
c. Turn thermostat to desired temperature.
d. Set manifold pressure to 4".
e. Replace valve.
a. Calibrate thermostat with exhaust
system running.
b. Have exhaust hood inspected and air
flow balanced.
a. Calibrate thermostat.
b. Replace thermostat.
c. Have exhaust hood inspected and air
flow balanced.