® MIRACLEAN GAS GRIDDLE SERIES 2000 MANUAL IMPORTANT: THIS MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR MODEL. USE THE MIRACLEAN® GAS GRIDDLE ONLY AS INSTRUCTED IN THIS MANUAL. KEEP A COPY OF YOUR BILL OF SALE. The date on the bill establishes the warranty period should service be required. If service is performed, it is in your interest to obtain and keep all receipts.
Page 2
PURCHASER SHOULD POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CON- SULTING THE LOCAL GAS SUPPLIER. WARNING Improper installation, adjustment, alteration, service or maintenance can Burns Shock cause property damage, injury or death.
Keating equipment is designed and manufactured to FIRST STEPS operate only on the type of gas specifi ed by the user and indicated on the serial plate located inside the POSITIONING door. The gas may be natural, propane or manufac- Keep appliance area free and clear of any combus- tured.
GAS GRIDDLE - SERIES 2000 The appliance must be isolated from the gas LEVELING supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).
STAND ASSEMBLY A. Gas pressure at manifold NATURAL GAS – 4.0 in. W.C. B. Gas pressure at manifold LP GAS – 10 in. W.C. (2.49kPa) C. Maximum incoming gas pressure NATURAL GAS – 7 in. W.C. (2.01kPa) D. Maximum incoming gas pressure LP GAS –...
GAS GRIDDLE - SERIES 2000 COOKING WITH YOUR MIRACLEAN® GRIDDLE becomes thicker. It becomes more of a meat cake than a hamburger. Therefore, the hamburger spatula You will fi nd that your new Miraclean® Griddle has has a strong cutting edge. superb heat transfer.
GAS GRIDDLE - SERIES 2000 3. Sprinkle with Keating Klenzer. Polish with a Damage done to the Miraclean® surface is irreparable. soft cloth (towel). It will sparkle like new in just NEVER USE A GRIDDLE STONE, BRICK OR SCREEN TO CLEAN THE MIRACLEAN® GRIDDLE SURFACE. a few minutes.
“non-stick” surface. For best cooking ranty, needs repairs other than routine cleaning, you are results and product appearance, use griddle oil for products requested to contact KEATING OF CHICAGO, INC. that require the surface to be conditioned. (1-800 KEATING).
GAS GRIDDLE - SERIES 2000 SERVICE PARTS ORDERING Parts may be ordered by part number by calling Keating at 1-800-KEATING or your service company. You may also order on-line at Keating’s part store, www.keatingofchicago.com. Refer to the Keating Miraclean® Griddle Limited Warranty for complete service and ordering information. The model/serial plate is located inside the cabinet.
GAS GRIDDLE - SERIES 2000 SERVICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
SERVICE ON/OFF SWITCH REMOVAL AND REPLACEMENT Servicing should only be performed by qualifi ed & 1. Lower the control panel by removing the screws. licensed service companies. 2. Disconnect the wires on the switch and remove switch. GAS VALVE REGULATOR ADJUSTMENT 3.
Page 15
GAS GRIDDLE - SERIES 2000 THERMOSTAT BULB PLACEMENT DETAIL (REFER TO CHART BELOW) A. BURNER COIL CHECK (“A” Reading. Thermostat contacts CLOSED - Gas Valve knob “ON”. Main burner should come ON.) 1. If the reading is more than 100 millivolts and the automatic valve still does not come one, replace the valve.
Page 16
MILLIVOLT CONTROL VALVE To check Resistance of the gas valve, connect one wire to the valve as shown. 1. Resistance between the THTP & TH terminals must be 11.5V±0.2V 2. Resistance between the THTP & TP terminals must be 10.0V±0.2V If resistance is outside of specifi...
GAS GRIDDLE - SERIES 2000 WIRING DIAGRAM GAS GRIDDLE WIRING DIAGRAM - 2011 WIRING DETAIL THERMOSTAT WHITE TO “TP” TERMINAL RED TO “TH/TP” ON ON GAS VALVE GAS VALVE TO “TH” ON GAS VALVE TO “TH/TP” ON GAS VALVE TO “PILOT”...