POST THIS LABEL IN A PROMINENT LOCATION ON YOUR UNIT. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
Adequate clearance for servicing and proper STANDARD operation must be maintained. ACCESSORIES Your Keating MIRACLEAN® is designed to be Keating griddle scraper serviced form the front, except for the rear field wire connections (electric input). Package of 10 scraper blades...
II INSTALLATION LEVELING Your MIRACLEAN® Griddle will operate at its highest efficiency when properly leveled. Place a level on the griddle plate from side to side. For griddles on legs, the This UNIT must be installed, inspected, calibrated and bottom foot adjustable.
ANSI/NFPA 70 or the Canadian Electrical Code CAN 22.2 as applicable. 1. Follow cleaning instructions on page 6. The Electric MIRACLEAN® Griddle is also equipped 2. Heat the MIRACLEAN® to 400°F for one hour. with a grounding lug next to the terminal block. For 3. Lower thermostat 350°F,...
CLEANING THE SURFACE. USE OF ICE MAY WARP THE GRIDDLE MIRACLEAN® SURFACE. The surface of the MIRACLEAN® Griddle is very durable and USE ONLY KEATING SUPPLIED CLEANING with proper care, following the procedures below, will last TOOLS AND KLENZER. many years.
A. Griddle Surface CLEANING With proper care, the MIRACLEAN® surface and its Proper care should be taken to fully clean the griddle unique cooking properties will last for many years. on a regular basis. However, nicks or dents in the griddle surface may...
V SERVICE DIAGNOSIS A. Trouble shooting The following diagnosis is only to be used as a guide to qualified personnel. Keating recommends that you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service company. PROBLEM PROBABLE CAUSE SOLUTION...
The model/serial plate is located on the front of the upper heat shield above the control panel. The serial and model numbers are necessary when ordering. WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN® Electric Griddle should be in place at all times. If plates are damaged or lost, replace them immediately. Figure 6-1...
VII WIRING DIAGRAMS NOTE: Griddles rated at 480 volts use type D-1 thermostats which include On/Off switches. Separate On/Off switches are not provided with these griddles. The following wiring diagrams are for griddles rated at 208-240 volts which have separate On/Off switches.
VIII KEATING GRIDDLE SPECIFICATIONS MODELS: STANDARD & FRONT TROUGH ONLY 24" DEEP MODELS 27x24 30x24 36x24 A M P S A M P S VOLTS VOLTS AMPS PER LINE-THREE PHASE AMPS PER LINE-THREE PHASE SINGLE SINGLE PHASE PHASE 2 ELEMENTS (2300 W EACH) 3 ELEMENTS (2300 W EACH) 42x24 / 48x24 60x24...
MODELS: STANDARD & FRONT TROUGH ONLY 30" DEEP MODELS 24x30 27x30 30x30 36x30 A M P S A M P S VOLTS AMPS PER LINE-THREE PHASE VOLTS SINGLE AMPS PER LINE-THREE PHASE SINGLE PHASE PHASE 10.7 2 ELEMENTS (3000 W EACH) 3 ELEMENTS (3000 W EACH) 42x30 / 48x30 60x30...
MODELS: STANDARD & FRONT TROUGH ONLY 36" DEEP MODELS 42x36 48x36 36x36 A M P S A M P S VOLTS VOLTS AMPS PER LINE-THREE PHASE AMPS PER LINE-THREE PHASE SINGLE SINGLE PHASE PHASE 10.1 13.4 11.3 15.0 17.9 13.4 3 ELEMENTS (3750 W EACH) 4 ELEMENTS (3750 W EACH) 72x36...
Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. 8901 W. 50th Street, McCook, Illinios 60525-6001 Phone: (708) 246-3000 FAX: (708) 246-3100 Toll Free 1-800-KEATING (In U.S.