Priority Door; Run Time; Starter Kill (Installation); Passive Or Active Arming - Autostart as2520 Installation Manual

Two way lcd automatic transmission remote starter
Table of Contents

Advertisement

Priority Door

This feature allows to unlock the driver's door by pressing
doors by pressing
a second time. In order to accomplish this, you must connect the
UNLOCK
module's unlock wire to the driver's door accordingly (i.e.: whatever mechanism that will allow only
the driver's door to unlock when the module's unlock wire is pulsed). The module's "priority door
access" AUX wire must then connect to the wire in the vehicle that will unlock all doors. Program
the AUX for priority door access accordingly.

Run Time

Use this function to configure the length of time the engine will be left running under remote control.
The module will allow the engine to run for either 4, 15 or 25 min. in gas mode and 9, 20 or 30 min.
in diesel mode. Standard default run time is 15 minutes in gas mode and 20 minutes in diesel
mode.

Starter Kill (Installation)

The module is equipped with a selectable passive or active-arming starter kill circuit that will
prevent the vehicle from being started with the ignition key when the module is armed. The starter
kill wire will provide a constant 500-mA. negative output when the system is armed (locked by
remote control) and can be connected to an external starter or ignition interrupt relay (see diagram
below). The starter kill circuit can be set to arm in either passive mode or active mode.
Caution!!!
When installing the starter kill, it is extremely important that pin 86 be wired to ignition: do not jump
it to pin 30 (damage to the vehicle could result).
Note: Installation of the starter kill system requires an external relay. (Not included!)

Passive or Active Arming

The module can be set to:
Active arming: the starter kill will not arm automatically. Press the
arm and the
UNLOCK
Passive arming: the starter kill will arm automatically if it is not armed by remote
within a 60-sec. delay. Press
Passive arming with 3-minute timeout: the starter kill will arm automatically after
3 minutes.

Flashing LED

There are three options available regarding the flashing LED:
a)
The LED flashes once the starter kill is activated (passive or active arming) and will
turn itself off once the user turns the key to the
b)
The LED is totally disabled and will not flash.
c)
The LED will flash once the starter kill is activated but requires pressing the
button to turn itself off. Failure to press the
even if the key is in the

Resetting the Module

The module is equipped with a reset function that allows the installer to erase all transmitter codes
from memory and return all the programming options to the factory default values.
Installation Guide
UNLOCK
button to disarm it.
to disarm.
UNLOCK
IGNITION ON
UNLOCK
position.
IGNITION ON
once and to unlock all other
button to
LOCK
position.
UNLOCK
button will make the LED flash
P. 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents