Toshiba RAV-SM563UT-E Service Manual page 68

Air-conditioner split type
Hide thumbs Also See for RAV-SM563UT-E:
Table of Contents

Advertisement

No.
Item
14
Central control
1) Setting at the central controller side enables to select
mode selection
2) RBC-AMT31E
15
Energy-save
1) Selecting [AUTO] mode enables an energy-saving to be
control
(By connected
2) The setup temperature is shifted (corrected) in the
outdoor unit)
3) Data (Input value room temp. Ta, Outside temp. To, Air
4) The setup temperature is shifted every 20 minutes, and
16
Louver control
The louver angle is displayed setting 0° as "Full close".
1) Louver
position
1) In the initial operation after power-ON, the position is
2) After then a louver position is stored in the microcomputer every time when position
2) Air direction
1) When pushing [LOUVER] button during operation, the louver starts swinging.
adjustment
2) When the louver has arrived at the desired position, push [LOUVER] again.
(Swing
operation)
Outline of specifications
the contents which can be operated on the remote
controller at indoor unit side.
[Last push priority] :
The operation contents can be selected from both
remote controller and central controller of the indoor
unit side, and the operation is performed with the
contents selected at the last.
[Center] :
Start/Stop operation only can be handled on the remote
controller at indoor unit side.
[Operation Prohibited] :
It cannot be operated on the remote controller at indoor
unit side. (Stop status is held.)
operated.
range not to lose the comfort ability according to input
values of various sensors.
volume, Indoor heat exchanger sensor temp. Tc) for 20
minutes are taken the average to calculate correction
value of the setup temperature.
the shifted range is as follows.
In cooling time : +1.5 to –1.0K
In heating time : –1.5 to +1.0K
automatically controlled according to the operating
status (COOL/HEAT).
is operated on the remote controller, and the louver operates at the position stored
in memory in the next operation and after.
* If the operation mode has been changed from COOL to HEAT, from HEAT to
COOL, or the power has turned off, the stored louver position is cleared and the
status returns to one in item 1).
The louver stops at that position.
Cooling
– 68 –
Remarks
(No display)
[CENTER] goes on.
[CENTER] goes on.
In a case of wireless type, the
display lamp does not change.
However, contents which can
be operated are same.
The status set in [CENTER]/
[Operation Prohibited] mode is
notified with the receiving sound
"Pi, Pi, Pi, Pi, Pi" (5 times).
Full close
Heating
45˚
103˚