9.0 OWNER INSTRUCTIONS

Assist owner with processing Warranty cards and/or online registration. Review Owners
Guide and provide a copy to the owner and guidance on proper operation and main-
teance. Instruct the owner or the operator how to start, stop and adjust temperature
setting. The installer should instruct the owner on proper operation and maintenance of
all other system components.

9.1 MAINTENANCE

1.
. Dirt should not be allowed to accumulate on the outdoor coils or other parts in the air
circuit. Clean as often as necessary to keep the unit clean. Use a brush, vacuum
cleaner attachment, or other suitable coil cleaning methods.
2. The outdoor fan motor is permanently lubricated and does not require periodic oiling.
3. If the coil needs to be cleaned, it should be washed with Calgon Coilclean (mix one
part Coilclean to seven parts water). Allow solution to remain on coil for 30 minutes
before rinsing with clean water. Solution should not be permitted to come in contact
with painted surfaces.
4. Refer to the furnace or air handler instructions for filter and blower motor maintenance.
5. The indoor coil and drain pan should be inspected and cleaned regularly to assure
proper drainage.
It is unlawful to knowingly vent, release or discharge refrigerant into the open air
during repair, service, maintenance or the final disposal of this unit. When the
system is functioning properly and the owner has been fully instructed, secure the
owner's approval.