Removing The Top Panel And Motor - Heat Controller RSGxxS-1D Series Installation, Operation & Maintenance Manual

Rsgxxs-1d series, rsgxxr-1d series, hrgxxs-1d series split system a/c & heat pump-1.5 to 5 ton
Table of Contents

Advertisement

#7 X 3/8" Self Tapping Screws
(Don't Exceed 3/8" long)
1/4" Χ 1-1/2" Hex Washer Head Concrete Screws
(3/16" Pilot Hole Needed. Pilot Hole Should Be1/4" Deeper
Than The Fastener Embedment)
Fig.8 FACTORY-PREFERRED TIE-DOWN METHOD
REQUIRED PARTS LIST

3.10 REMOVING THE TOP PANEL AND MOTOR

NOTE:
Damage will occur to condenser unit
if you remove fan bolts prior to cover removal.
When motor requires changing follow the steps below:
Step 1: Go into electrical panel, disconnect motor power lines.
IMPORTANT NOTE
Disconnect main power to unit. Severe burns and electrical shock will occur if
you do not disconnect main power.
Step 2: Remove cover (be careful of motor wires)
Step 3: Be sure to place fan cover unit on the ground as indicated in Fig. 9
IMPROTANT NOTE
Do not place or lean fan blades on ground or against surface.
Step 4: Remove fan motor by removing 5/16" bolts from cover.
Step 5: Remove fan blade from motor by removing 1/2" bolt and place fan on the ground.
Step 6: Reverse removal process to reinstall the fan and motor.
IMPROTANT NOTE
When connecting motor wires be sure to check motor direction.
For W + L Dimensions See Fig. 2
DETAIL B
1/2" bolt
Fig. 9 COVER AND FAN
15
SEE DETAIL B
Brackets:
2" width, 1/16" thickness,
height as required.
Brackets can be made
from commercially
available channel stock,
cut to size
and predrilled
5/16" bolts