Physical Data; Factory Charge R410A (Oz); Ecm Fan Motor & Blower; Fan Motor (Hp) - Heat Controller HTV Series Installation, Operation & Maintenance Instructions Manual

Two-stage geothermal heat pumps 2 to 6 tons
Table of Contents

Advertisement

Heat Controller, Inc.
General Information
T
CAUTION!
units in corrosive environments or in
locations subject to temperature or
humidity extremes (e.g., attics, rooftops,
etc.). Corrosive conditions and high
temperature or humidity can significantly
reduce performance, reliability, and service
life. Always move and store units in an
upright position. Tilting units on their
sides may cause equipment damage.
NOTICE!
cause excessive noise, and could cause component failure due to added vibration.
Model
Compressor (1 Each)
Model
Compressor (1 Each)

Factory Charge R410A (oz)

ECM Fan Motor & Blower
Blower Wheel Size (dia x w) - (in)

Fan Motor (hp)

Water Connection Size
Blower Wheel Size (dia x w) - (in)
Water Connection Size
HWG Connection Size
Swivel (in)
Swivel (in)
HWG Connection Size
Coax Volume
Swivel (in)
Volume (US Gallons)
Coax Volume
Vertical Upflow/Downflow
Volume (US Gallons)
Vertical Upflow
Standard Filter - 2" Pleated
HERV11, Quantity - in x in
Standard Filter - 1"
Weight - Operating, (lbs)
Throwaway, qty (in)
Weight -Packaged, (lbs)
Weight - Operating, (lbs)
Horizontal
Weight - Packaged, (lbs)
Standard Filter - 2" Pleated
All units have spring compressor mountings, TXV devices, and all units have ½" and ¾" electrical knockouts.
MERV11, Quantity - in x in
Weight - Operating, lbs
Weight - Packaged, lbs
All units have TXV devices, 1/2" and 3/4" electrical knockouts.
HTV/HTD/HTH SERIES
GENERAL INFORMATION
CAUTION!
DO NOT store or install
Failure to remove shipping brackets from spring-mounted compressors will
UNIT PHYSICAL DATA
UNIT PHYSICAL DATA
TWO STAGE HTV/HTD/HTH SERIES (60Hz Only)
GeoMax2 TWO-STAGE HTV/HTD SERIES (60 Hz Only)
24
24
58
58
/
1
9 x 7
½
1
1
1
1
0.76
0.76
28 x 20
1-24 x 28
28 x 20
1 - 28 x 24
266
276
266
276
18 x 31
2 - 18 x 18
266
276
T
CAUTION!
Failure to follow this caution may result in
personal injury. Sheet metal parts may
have sharp edges or burrs. Use care and
wear appropriate protective clothing, safety
glasses and gloves when handling parts
and servicing heat pumps.
36
Two-Stage Scroll
36
48
78
Two-Stage Scroll
78
81
/
1
2
2
11 x 10
11 x 10
½
1
1
1
1
1
1
1
0.92
0.92
1.24
28 x 25
32 x 25
1-28 x 30
1-30 x 32
28 x 25
32 x 25
1 - 28 x 30
2 - 16 x 30
327
337
327
416
337
426
20 x 35
20 x 40
1 - 12 x 20
1 - 18 x 20
1 - 20 x 25
1 - 20 x 24
327
5
337
4
CAUTION!
CUT HAZARD
48
60
60
81
144
144
1
1
11 x 10
1
1
1
1
1
1
1
1.24
1.56
1.56
36 x 25
1-30 x 36
36 x 25
1 - 16 x 20
1 - 16 x 20
416
443
1 - 20 x 30
1 - 20 x 30
426
453
443
453
20 x 45
2 - 20 x 24
416
443
426
453
70
70
156
156
1
11 x 10
1
1
1
1
1
1.56
1.56
36 x 25
1-30 x 36
36 x 25
443
453
443
453
20 x 45
2 - 20 x 24
443
453

Hide quick links: