Simrad AP24 Installation Manual page 28

Autopilots with autopilot computers
Hide thumbs Also See for AP24:
Table of Contents

Advertisement

3
It will power a SimNet compatible instrument
system. Hence SimNet to other equipment can be
supplied via the autopilot, see Figure 2-20, Figure
2-21 and Figure 2-22.
4
SimNet must be properly terminated, i.e. unless it
is a small system (see Figure 2-20) there must be
terminations at each end of the Simrad backbone.
The SimNet network has to be terminated according to
the number and type of products connected.
In a small system consisting of maximum 5 SimNet
products and a total length of 5 m SimNet backbone
cable you only need the SimNet power cable with built in
termination (red disc on cable plug).
For additional information about SimNet ask for the
separate SimNet Manual.
MODE
10
MENU
AUTO
12V SimNet supply
(SimNet cable with terminator)
RF25 Rudder Feedback
Figure 2-20 SimNet network, small system
IS20 Graphic
AP24
AP
24
10
TURN
1
1
PWR
STBY
Compass
Non SimNet
SimNet backbone
SimNet drop cable
AC12/AC42
5,5 m
T-joiner
5,5 m
5,5 m
T-joiner
Installation | 27