Installation Example - Build-Out (Dog-House) with Hor. Termination
•
The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
* Travis Ind. MIn. Vent Kit (SKU 98900168) Includes
a 4'' (102mm) section and horizontal termination.
NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm)
exterior wall, the termination may not fit flush against
the exterior wall. You may wish to place framing
around the termination to fill the gap.
Top View
NOTE:
1/2'' (13mm) Clearance to
sides and back of fireplace.
© Travis Industries
Installation
See "Vent Termination"
for full requirements.
Horizontal Termination*
4'' (102mm) Section*
(for qualified installers only)
SIDE OF FIREPLACE
Firestop
Insulation
Drywall
Optional Tile
4090709
Drywall
Optional Tile
NOTE:
In colder climates the fireplace may
require an insulated enclosure.
NOTE: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
Vapor
Barrier
41