Cleaning Behind the Firebox Liners

Front View of Firebox Liners
The firebox liners help trap flyash before it enters the exhaust blower. Remove the liners and clean the
area behind them following the directions below.
1. Open the door.
2. Remove the top liner. It is held in place with 3 tabs at the bottom and one large tab (and slot) on the
sides. To remove, lift it up and slide it out.
3. Remove the side liners. They have keyhole slots that fit over screws on the side of the firebox. Lift
them up, tilt them inwards, then remove.
© Travis Industries
Maintenance
4141230
Isometric View
(note how the top liner has a flange that bends down)