(4) Detaching and refitting the heat roller separation claws

Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Separate the right and left fuser unit (see
page 1-5-49).
2. Release four hooks and remove the fuser
guide from the right fuser unit.
3. Remove the springs and remove the heat
roller separation claws.
Caution
When removing them, be careful not to
touch the tip of the claw.
4. Replace the heat roller separation claws and
refit all the removed parts.
Caution
When fitting the separation claws, be careful
not to scratch the surface of the heat roller.
1-5-54
Hook
Hook
Right fuser unit
Figure 1-5-90
Heat roller
separation claw
Heat roller
separation claws
Figure 1-5-91
Heat roller guide
Hook
Hook
Spring
Right fuser unit