This is a copy of the label that accompanies
each HZ40E-NG and HZ40E-LP Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
Listed:
VENTED GAS FIREPLACE HEATER /
Certified for/Certifi e pour:
Tested to:
CAN/CGA-2.17-M91,ANSI Z21.88-2009/CSA 2.33-2009
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
4001172
NATURAL GAS: Model HZ40E-NG
Minimum supply pressure
5.0"
Manifold pressure
3.5"
Orifice size
#40
Maximum input
26,000 Btu/h
Minimum input
18,000 Btu/h
Altitude
0-4500
PROPANE GAS: Model HZ40E-LP
Minimum supply pressure
11" WC
Manifold pressure
10"
Orifice size
# 53
Maximum input
25,500 Btu/h
Minimum input
21,000 Btu/h
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si une trousse certifié est utilisé.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Fan (Part # 256-917)
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency Horizon™ HZ40E Gas Fireplace

COPY OF SAFETY DECAL

FOYER AU GAZ À ÉVACUATION
é
CANADA and U.S.A.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le HZ40E-NG
WC/C.E.
(1.25kPa)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
WC/C.E.
(0.87kPa)
DMS
Grandeur de l'injecteur
D bit
é
Calorifique
(7.61 kW)
l'altitude
(5.28 kW)
ft/pi
(0-1372 m)
É
QUIP A L'UISINE POUR GAZ PROPANE
É
CONCU POUR ETRE POELE: Mod le HZ40E-LP
(2.73 kpa)
Pression d'allimentation minimum
WC/C.E.
(2..49kPa)
Pression à la tubulure d' chappement lev e
DMS
Grandeur de l'injecteur
(7.47kW)
D bit
é
Calorifique
(6.15 kW)
l'altitude
ft/pi
(0-1372 m)
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
é
é
é
é
maximum selon
é
é
é
é
maximum selon
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
FPI Fireplace Products International Ltd. Delta, BC, Canada
SAFETY LABEL
Serial No./ No de serie
380
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Side Walls
A
Ceiling
B
D
B
F
Min. Mantel Height
C
A
C
Max. Mantel Depth
D
Alcove Width
E
E
Alcove Depth
F
DOOR SEAL: Please
check that the door is
(See Instruction Manual for
properly sealed
detailed instructions)
Made in Canada/ Fabrique au Canada
8" (203mm)
22" (559mm)
17" (432mm)
13" (330mm)
84" (1524mm)
36" (2134mm)
918-983