Step 2: Mount WWIS onto RWIU

Before aligning the two PCBs, be sure that the connectors are not bent. This
CAUTION!
causes irreparable damage to both PCBs.
1. Carefully align the connectors of the WWIS (P9~P10 and P12~P17) to the terminals on the
RWIU (J9~J10 and J12~J17) (shown in
Figure 24
Alignment of the WWIS onto the RWIU
2. Gently press the WWIS onto the RWIU. Ensure that the connections are solid by gently
pulling the WWIS away from the RWIU. If the connectors are properly seated, a slight
resistance is felt.

Step 3: Determine Proper Strata DK Slot Configuration

Use
Table 14
RWIU PCB can provide up to 16 or 32 Strata AirLink Handsets, depending on where it is
placed. The RWIU slot provides eight handsets. Each additional set of eight handsets requires
that an additional cabinet slot adjacent to RWIU be vacant.
RSTU or RDSU: Each RSTU or RDSU PCB connected to BSIA requires one slot. These
PCBs cannot occupy a slot that is left vacant to provide capacity for RDTU, RPTU, or RWIU,
as shown in
Table
Handsets; each RDSU/RSTS provides circuits for four Strata AirLink Handsets.
Strata AirLink Installation Guide
to determine the physical slot configuration for the RWIU in Strata DK424i. The
14. Each RSTU PCB provides circuits for up to eight Strata AirLink
5/00
Figure
24).
RJ45
RWIU System Installation
Step 2: Mount WWIS onto RWIU
45