24.8.10 Menu item 612 (cycle time)
24.8.11 Menu item 613 (cycle time)
58
Caution Risk of injury !
The testing program serves only for the checking of cycles and
functions. Maintenance and setting work should not be conducted
when running the testing program.
The following is the meaning values set:
0= normal sewing cycle, the testing program is turned off.
1= the sewing cycle is stopped after switching the valves of the
thread catcher on.
2= the sewing cycle is stopped after switching the valve of the
respective thread trimming system on.
3= the sewing cycle is stopped after switching each valve on.
Select the desired item with the keys "ñ" or "ò".
Press the "OK" key.
The breakpoint mode will be turned on.
Press the "ESC" key.
The control unit switches back to the main menu.
Start the testing program through the control panel, hand switches,
or the foot pedal.
The machine moves to the first breakpoint and stops.
The control panel will display an Info-No.
The information is intended for the DA Service.
Press the "OK" key two times.
The machine moves to the next breakpoint.
You can exit the breakpoint mode by switching off the main switch.
In this menu item the "cycle time from the sewing start back to the
loading position" can be ascertained.
Quit the menu item with key "ESC".
In this menu item the "cycle time from the sewing start to "clamp
open"" can be ascertained.
Quit the menu item with key "ESC".