Points to notice for Disassembly / Assembly
Note:
① When disassembling/(re)assembling, be sure to use the conductive mat (J5033) and wrist strap (J5033-5)
for static protection of electrical parts.
② Before disassembling, be sure to remove batteries or AC power wires.
③ When disassembling, make sure to memorize the processing state of wires and FPC, screws to be fixed
and their types, etc.
④ Because the low pass filter of the imaging CCD PCB is easily damaged, handle it with enough care.
Points to notice for Lead-free solder products
・ Lead-free solder is used for this product.
・ For soldering work, the special solder and soldering iron are required.
・ Do NOT mix up lead-free solder with traditional solder.
Note:
When "Seprating Front and Rear bodies","Disassembling Image PCB",and"Disassembling Bayonet",
be sure to perform"Reset of AF defocus compensation amount"by D2X adjustment software after reassembly.
WARNING
警告
�
Due to an internal high voltage area, take extra care not to
内部に高電圧部あり。カバーを外す時は感電に注意すること。
get an electric shock when detaching covers..
After removing covers, b e sure to discharge the main
カバーを外した後は、修理指針の指示に従ってメインコンデン
condenser according to the instructions of repair manuals .
サーの放電を必ず行うこと。
- D1 ・
-
VBA12001-R.3668.A