Points to notice for Disassembly / Assembly
Note:
①  When disassembling/(re)assembling, be sure to use the conductive mat (J5033) and wrist strap (J5033-5)
for static protection of electrical parts.
②  Before disassembling, be sure to remove batteries or AC power wires.
③  When disassembling, make sure to memorize the processing state of wires and FPC, screws to be fixed
and their types, etc.     
④ Because the low pass filter of the imaging CCD PCB is easily damaged, handle it with enough care.
  Points to notice for Lead-free solder products
 ・ Lead-free solder is used for this product.
 ・ For soldering work, the special solder and soldering iron are required.
 ・ Do NOT mix up lead-free solder with traditional solder.
Note:
When "Seprating Front and Rear bodies","Disassembling Image PCB",and"Disassembling Bayonet",
be sure to perform"Reset of AF defocus compensation amount"by D2X adjustment software after reassembly.
WARNING
警告
Due to an internal high voltage area, take extra care not to
内部に高電圧部あり。カバーを外す時は感電に注意すること。
get an electric shock when detaching covers..
After removing covers, b e sure to discharge the main
カバーを外した後は、修理指針の指示に従ってメインコンデン
condenser according to the instructions of repair manuals .
サーの放電を必ず行うこと。
- D1 ・
-