Installation

Select the best location

Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5. Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
6. Use a Metal Detector or Metal Scanner to locate
studs to prevent unnecessary damage to the wall.
CAUTION: Install the indoor unit
on the wall where the height from
the floors more than 2.4 m (8 ft).
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radia-
tion from the condenser is not restricted.
2. Ensure that the spaces indicated by arrows around
front, back and side of the unit.
3. Do not place animals and plants in the path of the
warm air.
4. Take the air conditioner weight into account and
select a place where noise and vibration are mini-
mum.
5. Select a place so that the warm air and sound from
the air conditioner do not disturb neighbors.
Rooftop Installations:
If the outdoor unit is installed on a roof structure, be
sure to level the unit. Ensure the roof structure and
anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
More than 10 cm
(3.9 inch)
More than 2.4m
(8 ft)
18 / 24 kBtu
more than 30 cm
(11.8 inch)
more than 70 cm
(27.6 inch)
36 kBtu
more than 30 cm
(11.8 inch)
more than 70 cm
(27.6 inch)
- 20 -
More than 20 cm
(7.9 inch)
More than 10 cm
(3.9 inch)
more than 30 cm
(11.8 inch)
more than 60 cm
(23.6 inch)
more than 30 cm
(11.8 inch)
more than 60 cm
(23.6 inch)