Field Settings Table - Daikin EDLQ036BA6VJU1 Installation Manual

Unit for air to water heat pump system
Hide thumbs Also See for EDLQ036BA6VJU1:
Table of Contents

Advertisement

Field settings table

Temperature values displayed on the digital controller (user interface) are in °C.
Temperature values in °C are between brackets. Conversion from °C to °F is for information only.
First
Second
code
code
Setting name
User permission level
0
00
User permission level
Weather dependent set point
1
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_TI)
03
Set point at high ambient temperature (Hi_TI)
Disinfection function
2
00
Operation interval
01
Status
02
Start time
03
Set point
04
Interval
Auto restart
3
00
Status
Backup/booster heater operation and space heating off temperature
4
00
Status
01
Priority
02
Space heating off temperature
03
Booster heater operation
04
Freeze-up protection function
Equilibrium temperature and space heating priority temperature
5
00
Equilibrium temperature status
01
Equilibrium temperature
02
Space heating priority status
03
Space heating priority temperature
04
Set point correction for domestic hot water
temperature
DT for heat pump domestic water heating mode
6
00
Start
01
Stop
02
Not applicable
DT for booster heater and dual set point control
7
00
Domestic hot water step length
01
Hysteresis value booster heater
02
Dual set point control status
Second set point heating
03
04
Second set point cooling
Domestic water heating mode timer
8
00
Minimum running time
01
Maximum running time
02
Anti-recycling time
03
Booster heater delay time
04
Additional running time at [4-02]/[F-01]
EDLQ036~054BA6VJU1 + EBLQ036~054BA6VJU1
Unit for air to water heat pump system
4PW56182-1
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
3
2/3
–4~41
14
(–10)
(–20~5)
59
50~68
(15)
(10~20)
104
77~131
(40)
(25~55)
77
77~131
(25)
(25~55)
Mon~Sun,
Fri
All
1 (ON)
0/1
23:00
0:00~23:00
158
104~176
(70)
(40~80)
10
5~60
0 (ON)
0/1
1 (ON)
0/1
0 (OFF)
0/1/2
95
57.2~95
(35)
(14~35)
3
0/1/2/3
0 (active)
Read
only
1 (ON)
0/1
32
5~95
(0)
(–15~35)
0 (OFF)
0/1
32
5~68
(0)
(–15~20)
18
0~36
(10)
(0~20)
3.6
3.6~36
(2)
(2~20)
3.6
0~18
(2)
(0~10)
0
Read only
0~7.2
0
(0~4)
3.6
3.6~72
(2)
(2~40)
0
0/1
1.8~43.2 /
18
77~131
(10)
(1~24 /
25~55)
44.6
41~71.6
(7)
(5~22)
5
0~20
30
5~60
3
0~10
50
20~95
95
0~95
Step
Unit
1
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1:00
hour
9
°F
(5)
(°C)
5
min
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1
min
5
min
0.5
hour
5
min
5
min
Installation manual