(g) Inspection procedures corresponding to detail of trouble
Sensor error
Is connector connection good?
YES
Is sensor resistance value good?
YES
Replace PCB.
◆ Discharge pipe sensor temperature characteristics
Temperature (˚C)
Resistance (kΩ)
0
5
10
15
20
25
30
35
40
45
50
55
60
65

Current cut

Does current cut operate when
operating inverter with compressor
wire disconnected?
YES
Is output voltage applied to all 3
phases of power transistor?
YES
Is there any shortcircuit?
YES
Inspect compressor.
NO
Correct connection.
NO
Temperature (˚C)
Resistance (kΩ)
164
70
127
75
99
80
78
85
62
90
50
95
40
100
32
105
26
110
21
115
17
120
14
125
12
130
10
135
NO
Defective inverter
NO
Defective inverter
NO
Secure space for suction
and blow out.
¡ Check compressor wiring visually.
¡ Check insulation resistance. (1 MΩ or over)
¡ Check coil wire resistance. (Few Ω)
Replace sensor.
◆ Sensor temperature characteristics
(Room temp., indoor unit heat exchanger
temp., outdoor unit heat exchanger
temp., outdoor air temp.)
8.7
7.3
6.2
5.3
(Broken wire)
4.5
3.9
3.3
2.9
2.5
2.2
1.9
(Shortcircuit)
1.6
1.4
1.3
If check results are normal,
compressor is locked.
47
-
-
[Broken sensor wire,
connector poor connection]
30
25
20
15
10
5
–10
0
10
20
30
40
Temperature (˚C)
[Open phase on compressor output
terminal, compressor lock]
50
60