(b) Air flow selection
(i)
Speed of inverter changes within the range of selected air flow.
Air flow selection
Inverter command speed
Auto
Air flow
Inverter command speed
HI
Air flow
Inverter command speed
MED
Air flow
Inverter command speed
LO
Air flow
(ii) When any protective function actuates, the operation is performed in the mode corresponding to the function.
(iii) Outdoor blower is operated in accordance with the inverter command speed.
(c) Detail of control in each mode (Pattern)
(i)
Fuzzy operation
During the fuzzy operation, the air flow and the inverter speed are controlled by calculating the difference between the room
temperature setting correction temperature and the suction air temperature.
(ii) Cooling thermostat operation
1)
Operating conditions
During the cooling fuzzy operation or when the speed obtained by the fuzzy calculation is less than -24 rps.
2)
Detail of operation
Item
Inverter speed
Indoor fan
Outdoor fan
(iii) Cooling "HI POWER" operation (HI POWER button on remote controller: ON)
The unit is operated continuously for 15 minutes regardless of the setting temperature.
1)
Detail of operation
Item
Inverter speed
Indoor fan
Outdoor fan
Notes (1) Protective functions will actuate with priority even during the "HI POWER" operation.
(2) Room temperature is not adjusted during the "HI POWER" operation

(8) Outline of dehumidifying operation

(a) After operating the indoor blower for 20 seconds from immediately after the start of operation, the indoor temperature is checked
and, based on the result of check, the cooling oriented dehumidifying or heating oriented dehumidifying is selected.
Cooling or heating oriented dehumidifying is selected again one hour after the first selection of the cooling or heating oriented
dehumidifying.
Model
SRK20ZD-S1
20~60rps
20~60rps
Model
SRK20, 25, 35ZD-S1
0 rps [Comp. stopped]
Stop
Model
SRK20ZD-S1
SRK25ZD-S1
60
Heating oriented dehumidifying
Low
Room temperature - Setting temperature (deg)
-
SRK25ZD-S1
20~70rps
Depends on inverter command speed.
20~70rps
7th speed fixed
20~52rps
5th speed fixed
20~34rps
2nd speed fixed
SRK50ZD-S1
10rps [10sec.] → 0rps [Comp. stopped]
Corresponds to fan speed switch.
2nd speed [1min.] → stop
SRK35ZD-S1
70
98
7th speed
4th speed
Cooling oriented dehumidifying
–3
20
-
SRK35ZD-S1
SRK50ZD-S1
20~98rps
20~98rps
5th~7th speed
20~58rps
3rd~5th speed
20~38rps
SRK50ZD-S1
90
2nd speed
High
15~90rps
15~90rps
15~60rps
15~30rps