Range Of Usage & Limitations; Exterior Dimensions - Mitsubishi Heavy Industries SRK20ZD-S1 Technical Manual

Hide thumbs Also See for SRK20ZD-S1:
Table of Contents

Advertisement

(2) Range of usage & limitations
Item
Indoor return air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Power source voltage
Voltage at starting
Frequency of ON-OFF cycle
ON and OFF interval

(3) Exterior dimensions

(a) Indoor unit
Models All models
A
73.5
207.5
50
25
53.5
Piping hole (ø65)
Models
840
Indoor unit
Installating board
693
450
182.5
50
63.5
Drain hose 515 (ø16)
Piping for gas 533.5 (ø12.7)
Piping for liquid 603.5 (ø6.35)
Piping hole (ø65)
All models
Cooling operation : Approximately 21 to 32˚C
Heating operation : Approximately 15 to 30˚C
Cooling operation : Approximately 21 to 43˚C
Heating operation : Approximately -5 to 21˚C
Max. 25m
Max. 15m (Outdoor unit is higher)
Max. 15m (Outdoor unit is lower)
Rating ± 10%
Min. 85% of rating
Max. 10 times/h
Max. 3 minutes
259
73.5
3
60
180
-
-
Unit: mm
3
Piping hole right
44
60
813
VIEW A
60
14.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents