Items Relating To The Time Code (601 - Sony SRW-5001 Operation Manual

Hd digital videocassette recorder format converter board digital betacam processor board rgb processor board
Table of Contents

Advertisement

Items Relating to the Time Code (601~)

Item number
Item
601
DF/NDF MODE
select
602
TIMER MODE
select
603
TCR MODE select
604
TC2 MODE SEL
Setting
Function
[drop frame]
Selects the timing mode for the time code generator and the
CTL counter.
non-drop frame
drop frame: drop frame mode ("DF" indication)
auto
non-drop frame: non-drop frame mode ("NDF" indication)
auto: Drop frame / non-drop frame mode is selected
Notes
• This setting is only active when the frame frequency of the
unit is 29.97 Hz or 30 Hz.
• When the [F7](TCG MODE) key is set to regene, the time
code generator is synchronized to the playback time code,
and therefore this setting is disabled.
CTL
Selects the mode for displaying time data.
[TC]
CTL: During playback the CTL signal recorded on the tape,
UBIT
TC: The time code value read by the time code reader, or
UBIT: The user bits inserted in the playback time code, or
[LTC]
Selects the time code read by the time code reader during
playback.
auto
LTC: LTC is read.
VITC
auto: If the playback speed is from –1/2 to +1/2 normal
VITC: VITC is read.
UBG
Selects the time data appearing in the second line.
TCG
UBG: Displays UBG.
UBV
TCG: Displays TCG.
UBR
UBV: Displays UBV.
CTL
UBR: Displays UBR.
VITC
CTL: Displays CTL.
auto
VITC: Displays VITC.
auto: Displays VITC when the playback speed is within the
LTC
[off]
LTC: Displays LTC.
off: Does not display time data in the second line.
automatically on the basis of the frame frequency of the
unit. For 29.97 Hz drop frame mode is selected, and for
30 Hz non-drop frame mode is selected. The setting of
the frame frequency mode is carried out with the
[F9](OTHERS CHECK)/ [F9] (SYSTEM) button.
or during recording the CTL signal being recorded on the
tape, is counted, and the tape running time is displayed
in hours, minutes, seconds, and frames.
the time code value generated by the time code
generator is displayed. Use item 603 to toggle between
VITC and LTC.
the user bits inserted in the time code being recorded
are displayed. Use item 603 to toggle between VITC and
LTC.
speed, VITC is read, and if outside this range LTC is
read.
range ±1/2 normal speed, and LTC if outside this range.
(Continued)
A-27
Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srw-5003Srw-5002Srw-5000

Table of Contents