Serial Interface Parameters

COMMAND STRUCTURE
COMMAND FUNCTION
INPUT TO PRINTER
PRINTER OUTPUT
SPECIAL NOTES
SATO Programming Reference
Section 6: Configuration Commands
<ESC>I2abcde
a
=
0
Baud rate, 9600 bps
1
Baud Rate, 19200 bps
2
Baud Rate, 38400 bps
3
Baud Rate, 57600 bps
b
=
0
8 Data bits
1
7 Data Bits
c
=
0
No Parity
1
Odd Parity
2
Even Parity
d
=
0
1 Stop Bit
1
2 Stop Bits
e
=
0
Single Item Buffer
1
Multi Item Buffer
2
X-On/X-Off Flow Control
3
Bi-Com 4
4
Bi-Com 3
Example:
See above
Placement:
Separate data stream sent to printer
Default:
Default value set by <ESC>PC command
To set the operating parameters of the RS232 Inferface for a job.
<ESC>
<ESC>I230011
<ESC>Z
There is no printer output as a result of this command.
1. The setting are stored in the EEPROM by this command and
they will remain in effect until a new <ESC>I2 command is
received. Cycling power will have no effect on these settings.
2. To change the value stored in the EEPROM, use the
<ESC>PC Printer Setting command or use the Printer Set-
ting Utility program contained on the CDROM shipped with
the printer.
3. All command parameters must be present in the data stream
sent to the printer.
4. Selecting X-On/X-Off, Bi-Com3 or Bi-Com4 will automatically
place the printer in the Multi Buffer mode.