Sharp LC-32X20E Service Manual page 48

Lcd colour television
Hide thumbs Also See for LC-32X20E:
Table of Contents

Advertisement

LC-32X20E/S/RU, LC-37X20E/S/RU
5) Repeat step 4) for points 4, 3, 2, and 1.
[Adjustment reference standard value]
Adjustment spec ± 0.002 Inspection spec ± 0.004 (point 1 and 2)
Adjustment spec ± 0.001 Inspection spec ± 0.002 (Excluding the above-mentioned)
* Adjusting procedure by use of [RS-232C]
1. Get ready the PC with COM port (RS-232C) running on Windows 95/98/ME/2000/XP operating system, as well as the RS-232C cross cable.
2. Start the unit with the RS-232C cable connected.
3. Start the terminal software. (The freeware readily available on the Internet will do.)
4. Make the following settings.
Baud rate
9,600 bps
Data LENGTH
8 bit
Parity bit
None
Stop bit
1 bit
Flow control
None
5. If the settings are correct, the terminal software indicates "ERR" against pressing of the "ENTER" key.
6. After the settings are done correctly, it is possible to make an adjustment by typing in the command shown in the table below and pressing the
"ENTER" key on the keyboard.
7. Command entry is successful if the terminal software indicates "OK" when the "ENTER" is pressed. If "ERR" is shown, retry to enter the command.
8. Send the process mode switching command to switch from the RS232C operation mode to the process mode.
KRSW0001: "ERR" is returned.
KKT10037: When "OK" is returned, the process mode becomes active. When "ERR", start over from KRSW0001.
9. Send each adjustment command.
RS-232C command list
Command
KYOF0000
Remote control disabled
OSDS0001
OSD display inhibited
SBSL0016
Light control level MAX
MSET0001
Background adjustment start
MSET0004
Initialization of adjustment value
LEV60928
Graduation 6 (928-graduation adjustment)
MG6G ****
Adjustment of G of graduation 6
MG6R ****
Adjustment of R of graduation 6
MG6B ****
Adjustment of B of graduation 6
LEV50800
Graduation 5 (800-graduation adjustment)
MG5G ****
Adjustment of G of graduation 5
MG5R ****
Adjustment of R of graduation 5
MG5B ****
Adjustment of B of graduation 5
LEV40656
Graduation 4 (656-graduation adjustment)
MG4G ****
Adjustment of G of graduation 4
MG4R ****
Adjustment of R of graduation 4
MG4B ****
Adjustment of B of graduation 4
LEV30528
Graduation 3 (528-graduation adjustment)
MG3G ****
Adjustment of G of graduation 3
MG3R ****
Adjustment of R of graduation 3
MG3B ****
Adjustment of B of graduation 3
LEV20352
Graduation 2 (352-graduation adjustment)
MG2G ****
Adjustment of G of graduation 2
MG2R ****
Adjustment of R of graduation 2
MG2B ****
Adjustment of B of graduation 2
LEV10184
Graduation 1 (176-graduation adjustment)
MG1G ****
Adjustment of G of graduation 1
MG1R ****
Adjustment of R of graduation 1
MG1B ****
Adjustment of B of graduation 1
MSET0003
Writing of adjustment value
Function
3 – 16
Remarks
0000 ~ 4095
0000 ~ 4095
0000 ~ 4095
Calculated value
0000 ~ 4095
0000 ~ 4095
Calculated value
0000 ~ 4095
0000 ~ 4095
Calculated value
0000 ~ 4095
0000 ~ 4095
Calculated value
0000 ~ 4095
0000 ~ 4095
Calculated value
0000 ~ 4095
0000 ~ 4095

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents