6.2.3 Motors (1/2)
•
Reader Unit
Electrical signal (target)
Name
M400 (R-CON)
Scanner motor
•
Printer Unit (1/2)
Electrical signal (target)
Name
M1 (DC-CON)
Main motor
M2 (FEED)
Pickup motor
M3 (DC-CON)
Horizontal registration
sensor shift motor
M4 (DC-CON)
Fixing motor
M5 (DC-CON)
Delivery motor
CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
Reference to general I/O address
circuit diagram I/O indication
A3-18-G
Reference to general I/O address
circuit diagram I/O indication
A3-20-I
A3-20-N
A3-17-N
A3-15-J
A3-9-N
IO-P01-0
IO-P01-1
0: CW
IO-P01-2
0: drive enabled
IO-P01-4
1→0: return to origin
IO-P01-5, 6
IO-P04-6
IO-P06-0
0: new current mode
P001-0
0: ON, 1: OFF
P008-3
0: lock
P003-0 to 3
P003-4 to 7
P001-3
0: ON, 1: OFF
P001-4
1: ON, 0: OFF
P008-5
0: lock
P010-0 to 8
Remarks
Clock signal
Default
Analog
Remarks
4-51