Installation Procedure - York HLCA-HLHA 07-36 Installation & Owner's Manual

Minisplit high wall air conditioner
Hide thumbs Also See for HLCA-HLHA 07-36:
Table of Contents

Advertisement

PARTS INSTALLATION
Part No.
Name of part
1
Installation plate
2
Mounting screw ST3.9x25-C-H
3
Clip anchor
Refrigerant
4
pipe
5
Remote controller
6
Remote controller holder
7
Seal
8
Drain elbow
NOTE: At least two of A, B, C aspect are free from blocking.
The air-conditioner can be connected only to a supply
with system impedance no more than 0.26 ohm. In case
necessary please consult your supply authority for system
impedance information.
I Cautions on remote controller installation
• Before installation, operate the remote controller to
determine its location in a reception range.
• Keep the remote controller at least 1 m apart from the
nearest TV set or stereo equipment.
• Do not install the remote controller in a place exposed to
direct sunlight or close to a heating source, such as a stove.
• Note that the positive and negative poles are right
positions when loading batteries.

INSTALLATION PROCEDURE

INDOOR UNIT
I Fixing
• Place the installation guide pattern on the designated
installation place and mark the hole position.
• Drill a hole and mount installation plate.
• After determining the pipe
hole position drill the hole at
a slight downward slant
towards the outdoor side.
Note: When installing
the refrigerant pipes from
others side. A hole must
be place to allow fall
towards the outdoor unit.
8
ENGLISH
J174_lastRev4.pmd
Q'ty
1
8
8
Parts you
Liquid side
must
Gas side
purchase
1
1
1
1
ø 65 mm
Outdoor
Indoor
8
15cm or more
5
Remote controller
Air blowing
direction
A
B
Loop the
connective
cable.
• Make 6 mm 4-6 holes, in the wall at the four corners of mouting
plate (bracket) then insert appropriate mounting devices.
• Install the mounting plate using 4-6 pieces of mounting screw
securely at four corners and tighten the screw completely.
Do not over tighten the screws and deform the back plate.
MODEL 07-09, 12 [220-240V, 50/60Hz]
15 cm or more to
Indoor unit outline
ceiling
20
12 cm or more
to wall
Left
refrigerant
pipe hole
ø65 mm
750
MODEL 12 [115V, 60Hz (UL)]
15 cm or more to
Indoor unit outline
ceiling
12 cm or more
to wall
Left
refrigerant
pipe hole
ø65 mm
3/14/05, 3:27 PM
1
2
3
Mounting screw B
ST2.9x10-C-H
6
4
Remote controller
holder
C
Installation plate
30
12 cm or more
to wall
70
Right refrige-
rant pipe hole
ø65 mm
Installation plate
12 cm or more
to wall
Right refrige-
50
815
rant pipe hole
ø65 mm