York HLCA-HLHA 07-36 Installation & Owner's Manual page 12

Minisplit high wall air conditioner
Hide thumbs Also See for HLCA-HLHA 07-36:
Table of Contents

Advertisement

I Wiring
Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.
Remark: All the wiring must be based on the wiring nameplate which shown on the model.
CAUTIONS
• Perform the wiring with sufficient capacity. Installation places legally require a short circuit isolator to be attached to
prevent electrical shock.
• Do not extend the power cable code by cutting.
• Power voltage should in the range of 90%~110% of rated voltage.
• The plug of the air conditioner takes a grounding leg, so clients should use a grounding socket so that the air
conditioner can be grounded efficiently.
• If the power cord is damaged, replacement should be conducted by qualified technician or a serviceman.
Note
Remark per EMC Directive 89/336/EEC
NOTE
For to prevent flicker impressions during the start of the compressor (technical process), following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution.
The distribution has to be of an low impedance, normally the required impedance reaches at a 32 A fusing point.
2. No other equipment has to be connected with this power line,.
3. For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for
products like washing machines, air conditioner or electrical ovens.
4. For power details of the air conditioner, refer to the rating plate of the product.
5. For any question contact your local dealer.
CAUTIONS
Cautions
• Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.
• Connect the connecting cable correctly and connect the connecting cable to terminal as identified with their respective marks.
• Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the surface of cables.
I
Electrical Connections
All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheeted cord (245 IEC 57 or H05RN-F).
Disconnecting device must have a contact separation of at least 3 mm.
Model : 07-21 (Cooling only)
Power supply
220-240V/1Ph/50Hz
220-230V/1Ph/60Hz
L
N
Model : 09-12 115V, 60Hz (UL) (Cooling only)
L
N
Power supply
115V/1Ph/60Hz
12
ENGLISH
J174_lastRev4.pmd
1 2(N)
Indoor
1 2(N)
Outdoor
Indoor
1
2
3
4
Outdoor
1
2
3
4
12
Model : 07-21 (Cooling and Heating)
Power supply
220-240V/1Ph/50Hz
220-230V/1Ph/60Hz
L
N
Model : 18-24 220-230V, 60Hz (UL) (Cooling only)
L
N
Power supply
115V/1Ph/60Hz
3/14/05, 3:27 PM
1 2(N) 3
4
Indoor
1 2(N) 3
4
Outdoor
Indoor
1 2(N) S
Outdoor
1 2(N) S