York HLCA-HLHA 07-36 Installation & Owner's Manual

Minisplit high wall air conditioner
Hide thumbs Also See for HLCA-HLHA 07-36:

Advertisement

MINISPLIT
HIGH WALL

AIR CONDITIONER

The units comply with one or more of the following marks - see unit for details.
J174_lastRev4.pmd
Installation & Owner's Manual
1
MODELS
HLCA-HLHA 07-36
HECB-HEHB 07-30
EN035M80000-000
3/14/05, 3:27 PM

Advertisement

Table of Contents
loading

Summary of Contents for York HLCA-HLHA 07-36

  • Page 1: Air Conditioner

    Installation & Owner’s Manual MODELS MINISPLIT HLCA-HLHA 07-36 HECB-HEHB 07-30 HIGH WALL AIR CONDITIONER The units comply with one or more of the following marks - see unit for details. EN035M80000-000 J174_lastRev4.pmd 3/14/05, 3:27 PM...
  • Page 2: Table Of Contents

    CONTENTS Safety Precautions ............. 3 Part Names ..............4 Manual Operation ............5 How the air conditioner works ........5 Optimal operation ............6 Preparation Before Installation ......... 6 Installation Procedure ..........8 Maintenance ............. 16 Operation tips ............17 Please read this installation Trouble Shooting Guide ..........
  • Page 3: Safety Precautions

    REQUIRED TOOLS EXTENDED PARTS 1. Screw driver 9. Manifold Guage 1. Refrigerant Pipe 2. Hexagonal wrench 10. Gas leak detector Models 07-09 12-21 24-36 3. Torque wrench 11. Vaccum pump 4. Spanner 12. Pipe clamp Liquid size 1/4 inch 1/4 inch 3/8 inch 5.
  • Page 4: Part Names

    PART NAMES INDOOR UNIT I INDOOR UNIT Front panel frame Infrared signal receiver Air inlet Front panel Remote controller Air filter Drain hose, refrigerant con- Horizontal air flow grille necting pipe Vertical air flow louver Connective cable Room temperature sensor Stop value Display panel Active Carbon Electrostatic Fiber Filter (Standard)
  • Page 5: Manual Operation

    MANUAL OPERATION Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. 1 Open and lift the front panel up to an angle until it remains fixed with a clicking sound. 2 Push the button until the AUTO indicator is lit, the unit will work in forced AUTO mode.
  • Page 6: Optimal Operation

    OPTIMAL OPERATION To achieve optimal performance, Please note the following: • Adjust the air flow direction correctly so that it is not directed on people. • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. •...
  • Page 7: English

    OUTDOOR UNIT PICTURES HLDA-HLJA 07-09, HEDB-HEJB 07-09 HLDA-HLJA 21-30, HEDB-HEJB 21-30, HLDA-HLJA 18 [220-230V, 60Hz (UL)] 301.5 141.5 560.1 HLDA-HLJA 36, HEDB-HEJB 36, HLDA-HLJA 12, HEDB-HEJB 12, HLDA-HLJA 24 [220-230V, 60Hz (UL)] HLDA-HLJA 09-12 [115V, 60Hz (UL)] 598.6 142.9 HLDA-HLJA 18, HEDB-HEJB 18 ENGLISH J174_lastRev4.pmd 3/14/05, 3:27 PM...
  • Page 8: Installation Procedure

    PARTS INSTALLATION Part No. Name of part Q’ty 15cm or more Installation plate Mounting screw ST3.9x25-C-H Clip anchor Parts you Liquid side Refrigerant must pipe Gas side purchase Remote controller Remote controller holder Seal Drain elbow Mounting screw B ST2.9x10-C-H NOTE: At least two of A, B, C aspect are free from blocking.
  • Page 9: Drain Hose

    I Wiring MODEL 18 [220-240V, 50/60 Hz], 21 Installation plate Indoor unit outline 15 cm or more • This indoor unit is ready for connection to the outdoor unit. to ceiling 12 cm or more 12 cm or more CAUTIONS to wall to wall •...
  • Page 10: Indoor Unit Fixing

    I Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole. • Hang the top of the unit onto the upper ridge of them in mounting plate. • Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. •...
  • Page 11 To this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves.
  • Page 12 I Wiring Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which shown on the model. CAUTIONS •...
  • Page 13: Wiring Connection

    Model : 24-30, 1Ph (Cooling and Heating) Model : 24-30, 1Ph (Cooling only) Power supply Power supply 220-240V/1Ph/50Hz 220-240V/1Ph/50Hz 220-230V/1Ph/60Hz 220-230V/1Ph/60Hz Indoor 1 2(N) 3 1 2(N) 3 Indoor 1 2(N) 3 Outdoor Outdoor Model : 30, 3Ph (Cooling only) Model : 30, 3Ph (Cooling and Heating) Indoor Indoor...
  • Page 14 Model : 24-30 Indoor Outdoor Terminal block of indoor unit Terminal block of indoor unit Terminal block of outdoor unit 1 2(N) 3 1 2(N) 3 1 2(N) Cord clamp Cord clamp Cooling only type Cooling & Heating type Cooling only type Cooling &...
  • Page 15: Electrical Work

    I Electrical Work Power Switch and Model Power Source Wiring size Fuse rating 220-240V ~ 50Hz 7000-9000 Btu/h 220-240V ~ 60Hz f f f f f 1.0 mm 115V~60Hz (UL) 220-240V ~ 50Hz 12000 Btu/h 220-240V ~ 60Hz f f f f f 1.5 mm 115V~60Hz (UL) 220-240V ~ 50Hz 2.5 mm...
  • Page 16: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and disconnect the power Household supply before cleaning. Drain Cleaner I Cleaning the indoor unit and remote controller CAUTION • Use a dry cloth to wipe the indoor unit and remote controller. •...
  • Page 17: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection • The compressor cannot restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 18: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not run. 1. Power Failure. 1. Wait for Power resume. 2. Fuse blown or circuit breaker 2. Replace the fuse or reset the open. breaker. 3. Voltage is too low. 3.
  • Page 19: Technical Specification

    TECHNICAL SPECIFICATION Technical Specifications : Ultra R22 - 50 Hz Indoor HLEA-HLKA Unit HLEA07 HLKA07 HLEA09 HLKA09 HLEA12 HLKA12 HLEA18 HLKA18 HLEA21 HLKA21 HLEA24 HLKA24 HLEA30 HLKA30 HLEA30 HLKA30 HLEA36 HLKA36 HLEA36 HLKA36 Models HLDA-HLJA Outdoor Unit HLDA07 HLJA07 HLDA09 HLJA09 HLDA12 HLJA12 HLDA18 HLJA18 HLDA21 HLJA21 HLDA24 HLJA24 HLDA30 HLJA30 HLDA30 HLJA30 HLDA36 HLJA36 HLDA36 HLJA36 V/Ph/Hz V/Ph/Hz V/Ph/Hz...
  • Page 20 TECHNICAL SPECIFICATION Technical Specifications : Ultra R22 - 60 Hz Indoor HLEA-HLKA Unit HLEA07 HLKA07 HLEA09 HLKA09 HLEA12 HLKA12 HLEA18 HLKA18 HLEA21 HLKA21 HLEA24 HLKA24 HLEA30 HLKA30 Models Outdoor HLDA-HLJA Unit HLDA07 HLJA07 HLDA09 HLJA09 HLDA12 HLJA12 HLDA18 HLJA18 HLDA21 HLJA21 HLDA24 HLJA24 HLDA30 HLJA30 V/Ph/Hz 220-230/1/60 Power Supply...
  • Page 21 TECHNICAL SPECIFICATION Technical Specifications : Ultra R22 - 60Hz (UL) Indoor HLEA-HLKA Unit HLEA09 HLEA12 HLEA18 HLEA24 Models Outdoor HLDA-HLJA Unit HLDA09 HLDA12 HLDA18 HLDA24 V/Ph/Hz 115/1/60 220-230/1/60 Power Supply Power Consumption 1200 1760 2600 Running Current 12.5 Refrigerant Type Refrigerant Charge 1070 1470...
  • Page 22 TECHNICAL SPECIFICATION Technical Specifications : Eco Ultra R407C - 50 Hz Indoor HEEB-HEKB Unit HEEB07 HEKB07 HEEB09 HEKB09 HEEB12 HEKB12 HEEB18 HEKB18 HEEB21 HEKB21 HEEB24 HEKB24 HEEB30 HEKB30 HEEB30 HEKB30 Models Outdoor HEDB-HEJB Unit HEDB07 HEJB07 HEDB09 HEJB09 HEDB12 HEJB12 HEDB18 HEJB18 HEDB21 HEJB21 HEDB24 HEJB24 HEDB30 HEJB30 HEDB30 HEJB30 V/Ph/Hz 220-240/1/50 or 380-415/3/50 Power Supply...
  • Page 23: Declaration Of Conformity

    Authorized Representative: CM Choi Shipping Manager YORK International (Northern Asia) Ltd. 15/F., Tower II, World Trade Square, 123 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong Telephone: (852) 2331 9286 Fax: (852) 2331 9840 Technical Service Division: Telephone: (852) 2331 9286 Fax: (852) 2304 0068...

This manual is also suitable for:

Hecb-hehb 07-30

Table of Contents