Sony DSR-300 Service Manual page 224

Digital camcorder index picture board camera adaptor
Hide thumbs Also See for DSR-300:
Table of Contents

Advertisement

9. Remove the setscrew (3 x 4) to remove the filter
knob.
10. Remove the three screws (B2.6 x 5) and remove
the shield case.
11. Remove the four screws (B3 x 6) and remove
the CCD unit from the Front unit assembly.
Note:
When handling the CCD unit, pay
attention not to stress each PA board.
12. First remove the holder for transportation from
the replacement CCD unit.
Then replace the defective CCD unit with it.
Note:
Re-use the holder for shipping back
the replacement unit.
Attachment
13. Assemble in the reverse order of removal.
Adjustment
14. After the replacement is completed, perform
several adjustments referring to Section 7-1-4.
Note on Adjustment.
In addition, perform MEMORY BACK UP
referring to Section 2-26-3 of menu "Page 24."
4-50
CCD unit
B3 x 6
B3 x 6
B2.6 x 5
B2.6 x 5
Shield case
Stopper screw
B3 x 6
Filter knob
CCD unit
Transportation holder
DSR-300/P(E)/V1