. . . . . Page 11 Various Setting 1
(For DSR-300)
PAGE 11 (NEXT
PREV
SETUP
:
OFF
READ OUT
:
FD
BLKG
:
20H
MAT DEST
:
EBU
EXIT MENU (YES PUSH)
(For DSR-300P)
PAGE 11 (NEXT
PREV
COMP LEV
:
525
READ OUT
:
FD
EXIT MENU (YES PUSH)
. . . . . Page 12 Matrix Center Value Setting
PAGE 12 (NEXT
PREV
MATRIX
STD
+40
R-G LEV
:
R-B LEV
:
+15
+4
G-R LEV
:
G-B LEV
:
+29
B-R LEV
:
+6
B-G LEV
:
+10
EXIT MENU (YES PUSH)
. . . . . Page 13 TEST MODE
PAGE 13 (NEXT
PREV
TEST
:
OFF
R-Y
:
ON
B-Y
:
ON
EXIT MENU (YES PUSH)
2-74
)
SETUP
READ OUT FD (Field): CCD switches in Field read mode
BLKG
MAT DEST Matrix destination setting (EBU/SMPTE)
Note:
In frame read out, higher vertical resolution can be obtained,
however, image lag is increasing. If shutter function is on with
frame read out, sensitivity drops in half against the normal.
)
COMP LEV 525/700 selection of color difference output
READ OUT FD (Field): CCD switches in Field read mode
MATRIX
)
R-G LEV
R-B LEV
G-R LEV
G-B LEV
B-R LEV
B-G LEV
Note:
Setting of current matrix coefficient (EBU/SMPTE) selected by
the MATRIX switch (and MAT DEST on Page 11) is displayed
on Page 12. The display show the current setting even when
the MATRIX switch setting is changed.
To rewrite the selected matrix data, change the center value.
For standard setting, refer to section 2-26-2.
TEST
)
R-Y
B-Y
ON/OFF control of setup
FM (Frame): CCD switches in Frame read mode
Blanking width setting (19/20/21H)
(Factory setting = EBU)
(pin 26)
FM (Frame): CCD switches in Frame read mode
Matrix switch (STD/H.SAT/FL) position display
R-G coefficient center value
R-B coefficient center value
G-R coefficient center value
G-B coefficient center value
B-R coefficient center value
B-G coefficient center value
TEST OFF: TEST SAW
TEST: 1
Displays 100 % TEST SAW.
TEST: 2
Displays 226 % TEST SAW.
TEST: 3
Displays 226 % TEST SAW in the lower side
of screen.
ON/OFF control of R-Y output
ON/OFF control of B-Y output
Standard Setting
OFF
FD
20H
EBU
Standard Setting
525
FD
DSR-300/P(E)/V1