Condensate 
(indoor models only) 
Condensate forma on can occur in high efficiency 
direct vent appliances.  Without proper drainage 
condensate will damage the heat exchanger.   
To prevent condensate damage follow these 
instruc ons. 
DO NOT 
Do not connect the condensate drain pipe directly 
to the rain sewer. 
Do not connect the condensate drain line with an 
air condi oning evaporator coil drain. 
MUST DO 
Use only vent that is approved and iden fied as 
acceptable for your par cular model. 
Slope the ven ng toward the appliance according 
to the vent manufacturers installa on instruc ons. 
All condensate must drain and be disposed of 
according to local codes. 
Use only corrosion resistant materials for the 
condensate drain lines such as PVC pipe or plas c 
hose. 
The condensate drain pipe (along its en re length) 
must be at least the same diameter as the drain 
line, (1/2 inch NPT).   
The end of the condensate drain pipe should be 
open to the atmosphere.  The end should not be 
under water or other substances.   
To minimize freezing of the condensate, run the 
condensate drain line through an interior wall or 
between insula on and an interior wall.
 
INFORMATION 
Water heaters have an integrated condensate 
collector. 
Regions of cold climate will create more 
condensate in the vent system.  The condensate 
collector should be used in cold climates. 
The condensate drain pipe should be as short as 
possible and have a downward pitch. 
If the condensate drain gets blocked, an diagnos c 
code will display on the controller. If this occurs, 
the condensate drain must be cleaned. 
The condensate trap will automa cally prime (self‐
prime) during opera on of the unit as condensate 
forms.  Condensate draining from the unit 
indicates that the trap is full and that there is no 
blockage in the condensate drain.  It is not 
necessary to add water to the condensate trap. 
A condensate neutralizer kit, 804000074, is 
available from Rinnai.  The kit allows condensate 
to flow through neutralizing media that raises the 
pH of the condensate to a level that will help 
prevent corrosion of the drain and public sewer 
system. 
Checklist for Ven ng and 
Condensate (indoor models only) 
□ 
Verify proper clearances around the vents and air 
intakes. 
 
□ 
Ensure you have used the correct ven ng 
products for the model installed and that you 
have completely followed the ven ng 
manufacturer's installa on instruc ons and these 
installa on instruc ons. 
□ 
Verify that the vent system does not exceed the 
maximum length for the number of elbows used.  