Rinnai RU80i Installation And Operation Manual

Rinnai RU80i Installation And Operation Manual

Direct vent tankless water heater
Hide thumbs Also See for RU80i:
Table of Contents

Advertisement

FOR INDOOR APPLICATIONS ONLY
RU80i .................... REU-KB2530FFUD-US
RU98i .................... REU-KB3237FFUD-US
FOR OUTDOOR APPLICATIONS ONLY
RU80e ................... REU-KB2530WD-US
RU98e ................... REU-KB3237WD-US
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
This manual provides information on the installation, operation, and maintenance of the water heater. For proper
operation and safety, it is important to follow the instructions and adhere to the safety precautions.
A licensed professional must install the water heater according to the exact instructions on pages 4-32.
The consumer must read the entire manual to properly operate the water heater and to have regular maintenance
performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed professional.
ANS Z21.10.3 ● CSA 4.3
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Direct Vent Tankless Water Heater
Installation and Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RU80i

  • Page 1 Direct Vent Tankless Water Heater Installation and Operation Manual FOR INDOOR APPLICATIONS ONLY RU80i ....REU-KB2530FFUD-US RU98i ....REU-KB3237FFUD-US FOR OUTDOOR APPLICATIONS ONLY RU80e ....REU-KB2530WD-US RU98e ....REU-KB3237WD-US ANS Z21.10.3 ● CSA 4.3 READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
  • Page 2: Table Of Contents

    If you have any questions or feel that the manual is incomplete contact Rinnai at 1-800-621-9419 Important Safety Information Safety Definitions This is the safety alert symbol.
  • Page 3: Safety Behaviors And Practices For The Consumer And Installer

    Safety Behaviors and Practices for the Consumer and Installer WARNING   Before operating, smell all around the appliance Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not area for gas.
  • Page 4: Installation Instructions

    A licensed professional must install the appliance, DO NOT inspect it, and leak test it before use. The warranty  Do not install the RU80i or the RU98i outdoors. will be voided due to improper installation.  Do not install the RU80e or the RU98e indoors.
  • Page 5: Prepare For Installation

    Prepare for installation  The appliance must be isolated from the gas supply Parts included piping system by closing its individual manual shutoff valve during any pressure testing of the gas  Tankless water heater supply piping system at test pressures equal to or ...
  • Page 6: Determine Installation Location

     Install as far away as possible from air inlet Rinnai offers Southeastern Filtration’s Scale Cutter vents. Corrosive fumes may be released through Water Conditioning System” that offers superior lime these vents when air is not being brought in scale prevention and corrosion control by feeding a through them.
  • Page 7 Direct Vent Terminal Clearances (Indoor Units) For indoor models, you must install a vent termination to bring in combustion air and expel exhaust. TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED CLOSED...
  • Page 8 Other Than Direct Vent Terminal Clearances (Outdoor Units) INSIDE CORNER DETAIL FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE AIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED Canadian Installations US Installations Description Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) 6 in (15 cm) for appliances ≤...
  • Page 9: Additional Clearances

    You must install a vent termination at least 12 or eve vent; or to a inches from the ground. 36" deck or porch 12" 2" RU80i, RU98i (1.52 m) vertically between terminals The vent for this appliance shall not terminate  60" Over public walkways; or ...
  • Page 10: Freeze Protection

    Combustibles models: inches (mm)  drain down solenoid valves are installed that will RU80i, RU98i inches (mm) automatically drain the unit if power is lost. Top of Heater 6 * (152) 2 *(51) These are available in a kit, 104000059. (The...
  • Page 11: Maximum Vent Length

    Example: If you have one elbow then your Maximum vent length maximum vent length is 35 feet (10.7 m). Maximum vent length with concentric venting If your actual length is greater than 15 ft (4.6 m) then move switch no. 1 (SW1) to 1.Determine the number of 90 degree elbows in the OFF.
  • Page 12: Checklist To Determine Installation Location

    Mount to Wall Checklist to Determine Installation Location □ The water heater is not exposed to corrosive compounds in the air. □ The water heater location complies with the wall installation clearances. brackets □ For indoor models, the planned venting will not exceed the maximum length for the number of elbows used.
  • Page 13: Installation Of Venting (Indoor Models Only)

    Refer to the manufacturer’s technical literature for specific part numbers and instructions. Listed and Tested Vent Manufacturer Telephone Contact Products Rolux Condensing Ubbink 800-621-9419 678-829-1666 www.rinnai.us Vent System Concentric to Twin Ubbink 800-621-9419 678-829-1666 www.rinnai.us Pipe Adaptor InnoFlue Vent System (single info@centrotherm.us.com...
  • Page 14 Do not use cellular core PVC/CPVC, Radel, ABS, or If it becomes necessary to access an enclosed vent galvanized material to vent this appliance. system for service or repairs, Rinnai is not responsible  for any costs or difficulties in accessing the vent Do not combine vent components from different system.
  • Page 15 Flue Installation with Concentric Venting (indoor models only) Install the venting termination according to the diagrams and instructions below. Horizontal Termination Slope the venting toward the appliance according to the vent manufacturers installation instructions. Dispose of condensate per local codes. Vertical Termination Slope the venting toward the appliance according to the vent manufacturers installation instructions.
  • Page 16 Flue Installation with Centrotherm Venting (indoor models only) Install the venting termination according to the diagrams and instructions below.  Comply with the exhaust clearances found in the Rinnai Operation and Installation Manual.  Only one appliance can be attached to the vent system.
  • Page 17: Twin Pipe Pvc/Cpvc Vent Installation

    Twin Pipe PVC/CPVC Vent Installation Rinnai has certified the Ubbink 3”/5” to 3”/3” Concentric to Twin Pipe Adaptor and other venting equipment to be used with the optional PVC/CPVC twin pipe venting system for use with the following condensing water heater models only: REU-KB3237FFUD-US (RU98i) and REU-KB2530FFUD-US (RU80i).
  • Page 18 The exhaust and air piping must be installed as instructed in this manual. The chimney must be used only for Rinnai Water Heater(s) vent chase. NO OTHER appliance or fireplace can be connected to the chimney. Exhaust and air piping materials must comply with this instruction. The chimney must be fitted with a sealed access opening to facilitate interior inspection.
  • Page 19  Locate the vent outlet where flue gases will not harm  If common venting is required, refer to Rinnai surrounding plants and/or cooling equipment. Common Vent Installation Manual (latest revision) for  Avoid locating vent where prevailing winds could...
  • Page 20 IMPORTANT CONSIDERATIONS FOR LOCATION (continued): OPTION 1: Calculation of equivalent piping lengths for venting system: For PVC/CPVC vent systems reduce the maximum allowable length for each elbow and termination type as Choose the vent type and fill out the calculation sheet follows : below.
  • Page 21 OPTION 2: Maximum Equivalent Vent Length Tables: Determine the number of 90 degree elbows in the vent system. (two 45 degree elbows count as one 90 degree elbow.) Refer to the tables below to find the maximum vent length based on the number of elbows and termination style. Natural Gas Units Total Equivalent Vent Length (Intake/outlet) for Twin Pipe 3"...
  • Page 22 Maximum Equivalent Vent Length Tables (continued): Propane Units Total Equivalent Vent Length (Intake/outlet) for Twin Pipe 3" PVC/CPVC 41 Feet Maximum Vent Length IPEX Concentric Snorkel Side Wall Tee Low Profile Termination Type Vent Kit Termination Termination Termination Termination Equivalent Length in feet (meters) (Already factored into the straight 20 (6.1) 10 (3.0)
  • Page 23 Adaptor Installation attempt to install or repair damaged components. If a gasket is damaged, these are available through Rinnai and NOTICE its distributors. Do not use gaskets from another For installation in Canada, field-supplied PVC/CPVC used manufacturer. for combustion venting must comply with CAN/CGA STEP 3: B149.1 (latest edition) and be certified to Type BH Gas...
  • Page 24 Adaptor Installation (continued) NOTICE STEP 5: For further details on listed PVC/CPVC venting material Apply lubricant to the gasket surface and coupling with table and proper handling and installation (e.g. priming, finger prior to component attachment To make the union gluing etc.), refer to the installation manual of the of the gasketed fittings into the PVC coupling easier, respective PVC/CPVC manufacturer.
  • Page 25 Installation of PVC/CPVC Vent and Intake Air Piping: Adaptor Installation Configurations: Note the correct position of combustion air inlet and gas flue outlet, as these are NOT interchangeable. For the correct position and design of the twin pipe gas flue outlet and combustion air inlet refer to the installation instructions supplied with the appliance.
  • Page 26 Certified PVC/CPVC Vent Termination Options Vent Termination Configurations WARNING There are three configurations for vent terminations that Danger of fire or bodily injury – Solvent cements and can be used: primers are highly flammable. Provide adequate 1.Concentric Termination (IPEX Concentric Vent Kit) - ventilation and do not assemble near heat source or open Allows for only one penetration through a wall or roof.
  • Page 27 Certified PVC/CPVC Vent Termination Options (continued) IPEX Concentric Vent Kit Assembly (System 636): MECHANICALLY FASTENED RAIN CAP: Once the proper location has been determined, cut a The Rain Cap must be installed with the supplied Stainless hole in the roof or wall large enough to Steel screw and lock nut, and in accordance with the accommodate the outer pipe.
  • Page 28 IPEX CONCENCTRIC VENT KIT (CVK) CLEARANCES: ACCEPTABLE VENTING CLEARANCES FOR IPEX CONCENCTRIC VENT KIT (CVK) TERMINATION 24” MIN Two or More Vent Terminals on same level Soffit Reference “General Clearance Ceiling Requirements” section of this guide for important considerations for locating vent termination under a soffit (ventilated or unventilated), eave, or deck/porch.
  • Page 29 Table 8: Approved PVC/CPVC Vent Configurations Rinnai 3" or Rinnai 3" or 4" 4" PVC/CPVC PVC/CPVC Concentric Concentric Side Wall Vertical Termination Termination Configuration Configuration Rinnai 3" or 4" Rinnai 3" or PVC/CPVC 4" PVC/CPVC Standard Snorkel upside down Termination "U"...
  • Page 30 Certified PVC/CPVC Vent Termination Options (continued) Kit Contents 3” and 4” Low Profile Vent Termination Kits Item Description The following information should be used in conjunction with the IPEX System 636 Installation Guide: Base (Two Holes)  Termination kits are to be tested and certified for use Cap (One Hole) with the brand of pipe-fitting-cement system that is to be utilized in the application.
  • Page 31 Certified PVC/CPVC Vent Termination Options (continued) Twin Pipe (PVC/CPVC) Terminations PVC/CPVC Sidewall (Tee and Snorkel) Terminations: Locate the vent and intake air termination using the following guidelines: The total length of the vent or intake air piping must 12” min not exceed the limits given in maximum equivalent Exhaust Vent vent length tables.
  • Page 32 Certified PVC/CPVC Vent Termination Options (continued) NOTE Vent Termination All figures shown in this section is in reference to flat roofs. Combustion air termination For heights of venting passing through a pitched roof, refer 12” above to NFPA 54/ANSI Z223.1-09 (table and figure 12.7.2) and/or 12”...
  • Page 33 Certified PVC/CPVC Vent Termination Options (continued) Apply a thin coat of cement evenly in the socket. NOTE Quickly apply a heavy coat of cement to the pipe and To prevent possibility of condensate freeze-up, do not insert pipe into fitting with a slight twisting motion install vent kits one above the other.
  • Page 34 Parts Information Ubbink® Concentric to Twin Pipe Adaptor Lubricant can be applied on the seals, only use the Ubbink approved lubricant that is Exhaust supplied in this package Vent Combustion Air ULc 636 Gas Vent-BH Class IIC-110°C/230°F where applicable) 4004535 Physical Data in inches (mm) Nominal Part #...
  • Page 35 Parts Information (continued) Vent Components and Assigned Equivalent Lengths: The following fittings and accessories (by others) are certified for use with the abovementioned condensing products: Approved PVC/CPVC Termination Components OEM # or Product Equivalent Diagram Cert. Description Lengths (Ft.) 196006 /197009 (3 Inch) IPEX (Purchased PVC/CPVC- FGV...
  • Page 36 PVC/CPVC Equivalent Vent Length Calculation Sheet Equivalent Vent Length Calculation Sheet Number of Equivalent Vent Total Equivalent Fitting / Termination Type fittings Length Length 90 elbow 45 elbow IPEX Low Profile Termination IPEX 4" Concentric Termination IPEX 3" Concentric Termination 3"...
  • Page 37: Condensate (Indoor Models Only)

    All condensate must drain and be disposed of  A condensate neutralizer kit, 804000074, is according to local codes. available from Rinnai. The kit allows condensate  Use only corrosion resistant materials for the to flow through neutralizing media that raises the...
  • Page 38: Installation Of Plumbing

    Isolation valves are included with this water heater.  Do not place any other type valve or shut off Rinnai strongly recommends the installation of device between the relief valve and the water isolation valves on the cold and hot water lines heater.
  • Page 39 Isolation Valves and Pressure Relief Valve The isolation valves provide the ability to isolate the water heater from the structure’s plumbing and allow quick access to flush the heat exchanger. Check with local codes to determine if a pressure and temperature relief valve is required.
  • Page 40 Piping Diagram for Basic Installation Cold water Water inlet drain plug connection Condensate Condensate Hot water drain line trap drain plug outlet The condensate drain pipe (along its entire length) must be at least the same diameter as the drain line, (1/2 inch NPT). Refer to the Condensate section in the venting instructions...
  • Page 41: Checklist For Plumbing

    □ Check for proper water pressure to the water corrosive.) heater. Minimum water pressure is 50 psi. Rinnai  Use approved connectors to connect the unit to recommends 60-80 psi for maximum the gas line.
  • Page 42  Any compound used on the threaded joint of the Pipe Sizing Table - Natural Gas gas piping shall be a type which resists the action Schedule 40 Metallic Pipe of liquefied petroleum gas (propane / LPG). Inlet Pressure: less than 2 psi (55 inches W.C.) ...
  • Page 43: Connect Electricity

    Connect Electricity Adjust for High Altitude WARNING On the SW1 DIP switch (tan switches), set switches 2 and 3 to the values shown in table below for your Do not use an extension cord or an adapter plug with altitude. The default setting for the appliance is 0- this appliance.
  • Page 44: Installation Of Temperature Controller

    Controllers cannot be wired in series. connections inside the unit. Do not connect the temperature controller to the Maximum 4 Controllers Rinnai 120VAC terminals provided for the optional solenoid Water drain valves. Heater Indoor models have their controller built into the front panel.
  • Page 45: Mounting The Controller

    Mounting the controller 1. Make three holes in the wall as shown. Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2. Run the cable between the controller and the water heater or the controller and another controller. 3.
  • Page 46: Final Checklist

    Final Checklist □ Check the gas lines and connections for leaks. □ Confirm that the gas inlet pressure is within limits. □ The water heater is not subject to corrosive □ compounds in the air. Confirm that the water heater is rated for the gas □...
  • Page 47: Technical Data

    Technical Data Specifications RU80i RU98i RU80e RU98e Minimum Gas Consumption Btu/h 15,200 Maximum Gas Consumption Btu/h 152,000 199,000 152,000 199,000 0.26 - 8.0 GPM 0.26 - 9.8 GPM 0.26- 8.0 GPM 0.26 - 9.8 GPM Hot water capacity (Min - Max) * (1.0 - 30 L/min)
  • Page 48: Dimensions

    Dimensions Inches (millimeters) RU80i, RU98i All Models ø 5.4 (137) 10.1 (257.7) 2.0 (52) DIMENSION Inches (mm) 8.7 (222) (70.1) A (GAS) 1.6 (40.2) A (COLD) 2.0 (50.2) A (HOT) 1.6 (41.2) RU80e, RU98e A (CONDENSATE 0.9 (22.4) 10.1 (257.5) 0.6 (15)
  • Page 49: Pressure Drop Curve

    RU98 Water Flow (gpm) The chart below only applies to incoming water temperatures of 70°F (21°C) or less. For NOTICE incoming water temperatures greater than 70°F (21°C) please contact Rinnai. Outlet Flow Data RU98 RU80 delta T - Temperature Rise (°F)
  • Page 50: Ladder Diagram

    Ladder Diagram FF MODEL ONLY KB Series Manual...
  • Page 51: Recirculation Mode

    Recirculation Mode recommendations. The Rinnai water heater has the ability to control a recirculation pump. Two modes are available, 4. Adjust the dip switch by moving the 4th switch in Economy and Comfort, which recirculate the water in the whie set of switches (SW2) to ON.
  • Page 52 Recirculation Mode Sequence of Operation Typical Pump ON Intervals* Rinnai DIP switches (SW2 - white switches, #4, #8) should be (minutes) Temperature set correctly for recirculation and mode. The Rinnai Setting Economy Comfort water heater should be turned on. °F Mode...
  • Page 53: Operation Instructions

    RU98e ....REU-KB3237WD-US Important Facts about your Water Heater Thank you for purchasing a Rinnai Tankless Water Heater. For proper operation and safety, it is important to follow the instructions and adhere to all safety precautions. Read all of the instructions and the warranty thoroughly before operating this water heater. Keep this manual in a safe place.
  • Page 54: Consumer Operation Guidelines For The Safe Operation Of Your Water Heater

    Consumer Operation Guidelines for the Safe Operation of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. ...
  • Page 55: How To Use The Temperature Controller

    Rinnai provides a “Scale Control System” that offers superior lime scale prevention and  Keep the area around the appliance clear and free...
  • Page 56: How To Set The Temperature

    How to Set the Temperature This water heater requires a minimum flow rate to operate. This rate can be found on the specification page in this manual. In some cases when you are not getting hot water or if the water alternates between hot and cold, it is due to the water flow being below or close to the minimum flow rate.
  • Page 57 Temperatures Available with a Controller The water heater can deliver water at only one temperature setting at a time. The available temperatures are provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water. To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off”...
  • Page 58: Diagnostic Codes

    Temperature Options Without a Temperature Controller The default temperature setting for this appliance installed without a temperature controller is 120° F (49° C). If desired, the temperature setting can be changed to 140° F (60° C) by adjustment of a switch. In the SW1 tan switches, set switch 5 to ON to obtain 140°...
  • Page 59: Diagnostic Codes And Remedies

    Diagnostic Codes and Remedies WARNING Some of the checks below should be done by a licensed professional. Consumers should never attempt any action that they are not qualified to perform. Code Definition Remedy Power interruption during Bath Fill (Water will not flow when Turn off all hot water taps.
  • Page 60 LC2,…) Off button on the temperature controller 5 times. Repeated LC codes will eventually lockout “LC”) the water heater. Please call Rinnai technical department. Maintenance has been Indicates a licensed professional performed maintenance or corrected an issue. performed Clean inlet water supply filter.
  • Page 61: Required Maintenance

    Required Maintenance The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be per- formed by a licensed professional. The licensed professional must verify proper operation after servicing. WARNING To protect yourself from harm, before performing maintenance: ...
  • Page 62: Pressure Relief Valve

    WARNING Freeze Protection Make sure that in case of freezing weather that the Testing the pressure relief valve should only be water heater and its water lines are adequately performed by a licensed professional. Scalding hot protected to prevent freezing. Damage due to water may be released under pressure.
  • Page 63: Flushing The Heat Exchanger

    An LC0~LC9 or “00” or 58 diagnostic code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. Rinnai strongly recommends installation of isolation valves to allow for flushing of the heat exchanger.
  • Page 64: Manual Draining Of The Water Heater

    Manual draining of the water heater WARNING To avoid burns, wait until the equipment cools down before draining the water. The water in the appliance will remain hot after it is turned off. If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.
  • Page 65: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION This direct-vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 66: Replacement Parts

    Replacement Parts The Technical Sheet which is located inside the front cover of the water heater contains a complete Gas Control Assembly Electrode / Flame Rod illustrated parts list. Tech Sheet Item No. Gas Control Assembly Electrode / Flame Rod Kit 116, 117 Fan Assembly / Motor Heat Exchanger...
  • Page 67 48 months (a total of 60 months labor coverage from date of purchase), when used in a residential hot water application, if the product is registered within 30 days of purchase at www.rinnai.us/ product-registration or by calling 1-866-RINNAI-1 (746-6241), except registration is not required in California and Quebec.
  • Page 68 Rinnai determines that repair of a product is not possible, Rinnai may replace the product with a comparable product at Rinnai’s sole discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
  • Page 69 Limitation on Warranties No one is authorized to make any other warranties on behalf of Rinnai America Corporation. Except as expressly provided herein, there are no other warranties, expressed or implied, including, but not limited to warranties of merchantability or fitness for a particular purpose, which extend beyond the description of the warranty herein.
  • Page 70 Chauffe-eau d’intérieur sans réservoir à ventilation directe Manuel d'installation et POUR LES APPLICATIONS INTÉRIEURES SEULEMENT d'utilisation RU80i ... REU-KB2530FFUD-US RU98i ... REU-KB3237FFUD-US POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT RU80e ..REU-KB2530WD-US RU98e ..REU-KB3237WD-US ANS Z21.10.3 ● CSA 4.3 LIRE TOUTES LES INSTRUCTIONS SOIGNEUSEMENT AVANT D’INSTALLER OU D’EXPLOITATION DE CETTE CHAUFFE-EAU.
  • Page 71 Nous allons cependant continuer à vous contacter avec les informations pertinentes pour le produit vous inscrit ou vous rendre compte avec nous. Si vous avez des questions ou se sentent que le manuel est incomplète, veuillez communiquer avec Rinnai au 1-800-621-9419.
  • Page 72: Les Pratiques Et Les Comportements De Sécurité Pour Les Consommateurs Et Les Installateurs

    Les pratiques et les comportements de sécurité pour les consommateurs et les installateurs AVERTISSEMENT   Utilisez seulement votre main pour pousser ou Avant d'exploitation, une odeur tout autour de la tourner le bouton de contrôle des gaz. Ne jamais zone de l'appliance pour le gaz.
  • Page 73: Installation D'instructions

    Un professionnel agréé doit installer l'appareil, NE FAITES PAS inspecter et fuite de le tester avant des utiliser. La  Le RU80i et RU98i n'est pas prévu pour une garantie sera être annulée en raison de la mauvaise installation à l'extérieur. installation.
  • Page 74: Préparez-Vous À L'installation

    Préparez-vous à l'installation  L'appareil et sa vanne de gaz doivent être Pièces incluses débranchés de la conduite d'alimentation en gaz  Chauffe-eau sans Réservoir durant les essais du système en pression dépassant 1/2 psi (3.5 kPa ou 13,84 pouces de hauteur de ...
  • Page 75: Déterminez L'endroit D'installation

    Installez le chauffe-eau aussi loin que possible des par l'eau dure définie à haute température. hottes de ventilation d'échappement. Un kit de traitement de l'eau est disponible depuis Rinnai. Ce kit  Installez aussi loin que possible des bouches d'air fournit un contrôle de la prévention et à...
  • Page 76 Espacements pour terminaison de cheminée (ANS Z21.10.3, CSA 4.3) Vous devez installer une fin de vent à TERMINATION DÉTAIL D'ANGLE INSIDE Terminaison INTÉRIEUR COR NER DETAIL apporter dans l'air de combustion et d'expulser des gaz d'échappement. Clearance in Dédouanement en Ref.
  • Page 77 (0.91 m) à évent  terminaux au soffite ou eve ventilé RU80i, RU98i: Vous devez installer une résiliation de vent même niveau au moins 12 pouces du sol ou non aérée ; ou à un 36" pont ou un porche 12"...
  • Page 78 Sur le côté Sur le côté Vers l'avant to side Vers l'avant to side to floor/ground to floor/ground Vers le sol Vers le sol Modèles d'intérieur: RU80i, RU98i Modèles extérieurs: RU80e, RU98e Jusqu'à Jusqu'à Jusqu'à Jusqu'à matières matières matières matières...
  • Page 79 microcommutateur N° 1 (SW1) en position OFF. Longueur maximale pour la ventilation  Si la longueur fait plus de 9' (2,7 m) passez le concentriques microcommutateur N° 1 (SW1) en position OFF. 1. Déterminez le nombre de coudes à 90° dans le ...
  • Page 80 En outre, les électrovannes devraient être connectés électriquement à un parasurtenseur avec terminaux. Cela permet les électrovannes à exploiter si le chauffe-eau est désactivé en raison d'un code de diagnostic. Les fonctionnalités de protection de gel n'empêchera pas la tuyauterie externe du point de congélation. Il est recommandé...
  • Page 81: Liste De Verification Pour Déterminez

    Bâti à murer Liste de vérification pour déterminer l'endroit d’installation □ Le chauffage de l'eau n'est pas corrosifs composés dans l'air. □ L'emplacement de chauffage de l'eau est parenthèses conforme avec les dégagements. d'installation de □ (Modèles d'intérieur) La ventilation prévue ne dépassera pas la longueur maximale pour le nombre de coudes utilisé.
  • Page 82: Installation De La Mise À L'air Libre

    S'il devient nécessaire d'accéder à un système d'évacuation combustion. fermée pour le service ou les réparations, Rinnai n'est pas  Éviter les trempettes ou courbure dans vent horizontal responsable des frais ou des difficultés à accéder au s'exécute en installant des supports par le vent du...
  • Page 83 Installez la résiliation ventilation selon les diagrammes et les instructions ci-dessous.  Respecter les dégagements de gaz d'échappement dans AVERTISSEMENT l'opération Rinnai et le manuel d'Installation.  Un seul appareil peut être attaché au système de ventilation. N'utilisez pas de cellulaire en PVC, CPVC, Radel, ...
  • Page 84 Installation de conduit de cheminée (Centrotherm, modèles d'intérieur) Installez la résiliation ventilation selon les diagrammes et les instructions ci-dessous. Longueur maximale de Vent à l'aide de coude court Longueur maximale de Vent à l'aide de coude de rayon long rayon (Apport est court coude UV protégées 90°) (Apport est long coude UV protégées 90 °) Nombre de...
  • Page 85: Condensat

    Pente la ventilation vers l'appliance selon les  Une trousse de neutralisant de condensat, instructions d'installation du fabricant évent. 804000074, est disponible chez Rinnai. La trousse  Rejetez le condensat en respectant les normes permet de condensat de circuler à travers les locales.
  • Page 86: Installation De La Tuyauterie

    Elle doit permettre un Vannes d'isolement sont inclus dans cette chauffe-eau. drainage complet de la soupape et de la conduite. Rinnai recommande fortement l'installation de vannes  Ne pas placer toute autre soupape de type ou fermer d'isolement sur les lignes de l'eau chaude et froide.
  • Page 87 Installez Valve à Bille / Valve de dégagement de pression Les soupapes d'isolement offrent la possibilité d'isoler le chauffe-eau de la structure plomberie et de permettre un accès rapide à vider l'échangeur de chaleur. Vérifiez auprès des codes locaux pour déterminer si une soupape de pression et de température est nécessaire.
  • Page 88 Tuyauterie recommandée pour installation de base Eau froide Bonde d’eau Canalisation Bonde de piège Eau chaude condensat condensate Le tuyau de vidange de condensat (le long de sa longueur) doit être au moins le même di- amètre que la ligne de drain, (1/2 pouce TNP). Reportez-vous à...
  • Page 89: Liste De Verification Pour Tuyauterie

    Utilisez toujours des connecteurs approuvés pour chauffage de l'eau. Pression d'eau minimum est raccorder l'unité sur la conduite de gaz. Purgez de 50 psi. Rinnai recommande de 60-80 psi pour toujours la conduite de gaz de tous débris éventuels des performances optimales.
  • Page 90  Tout composé utilisé sur la jonction filetée du tuyau Table - gaz naturel de gaz doit être d'un type qui résiste à l'action du gaz Tuyau métallique annexe 40 propane ou naturel. La pression Inlet : moins de 2 psi (55 pouces W.C.) ...
  • Page 91: Reliez L'électricité

    Reliez l'électricité Ajustez à l'haute altitude Définissez les valeurs indiquées dans le tableau ci- dessous pour votre altitude commutateurs 2 et 3 AVERTISSEMENT (SW1, commutateurs fauve). Le paramètre par N'utilisent pas une rallonge ou un adaptateur défaut pour l'appliance est 0-2000 ft (0-610 m) avec brancher avec cet appareil.
  • Page 92: Installation De Le Contrôleur De Température

    Installation de le contrôleur de Montage du contrôleur température 1. Faire trois trous dans le mur, comme le montre. AVERTISSEMENT Outline of Remote Désactiver le pouvoir. Ne pas tenter de connecter les securing screw contrôleurs de température avec le pouvoir. Bien que le contrôleur est un dispositif de basse tension, il y a 1-21/32"...
  • Page 93: Liste De Vérification Finale

    □ Confirmer que la pression du gaz inlet est dans les Liste de vérification finale limites. □ Le chauffage de l'eau n'est pas corrosifs □ Confirmer que le chauffe-eau est coté pour le composés dans l'air. type de gaz fourni. □...
  • Page 94: Diagramme En Escalier

    Diagramme en escalier NEUTRE PHASE POMPE RELAIS 3 FUSIBLE 10 A ANTI-FOUDRE CONTACT DE DÉTECTION DE GEL RELAIS 2 ANTI-FOUDRE RELAIS 1 ALLUMAGE TERRE ALIMENTATION D'ÉNERGIE DE COMMUTATION 170 V CC 12,6 V 40 V CC 5 V CC 0-50 V CC ÉLECTRO- DÉTECTEUR VANNE À...
  • Page 95 RU98e ..REU-KB3237WD-US Faits importants sur votre chauffe-eau Je vous remercie pour l'achat d'un chauffe-eau sans réservoir Rinnai. Pour le bon fonctionnement et la sécurité, il est important de suivre les instructions et de respecter les mesures de sécurité. Toutes les instructions et la garantie lire attentivement avant d'exploitation cette chauffe-eau. Gardez ce manuel en lieu sûr.
  • Page 96: Directives D'opérations Du Consommateur Pour Le Fonctionnement Sécuritaire De Votre Chauffe-Eau

    Directives d'opérations du consommateur pour le fonctionnement sécuritaire de votre chauffe-eau À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, il peut en résulter un départ d'incendie ou une explosion, causant dégâts matériels, blessures corporelles ou même mort.
  • Page 97: Comment Utiliser Le Contrôleur De Température

    Comment utiliser le contrôleur de température Dimensions (pouces): 3.5 W x 4.75 H x 0.75 D Le contrôleur de MC-91-2 est le contrôleur de température standard qui est fourni avec l'appareil de chauffage de l'eau. Sur les modèles de l'intérieurs, elle est intégrée dans le panneau avant. Le contrôleur de MCC-91-2 est pour des applications commerciales et hydroniques nécessitant des températures plus élevées.
  • Page 98: Comment Définir La Temperature

    Comment définir la température Cette chauffe eau nécessite un débit minimum à exploiter. Ce taux se trouvent sur la page de spécification dans ce manuel. Dans certains cas lorsque vous n'obtenez pas l'eau chaude ou si l'eau alterne entre le chaud et le froid, c'est en raison du débit de l'eau étant ci-dessous ou à...
  • Page 99 Plages de température avec un contrôleur de température Le chauffe-eau peut fournir l'eau à un seul réglage de la température à la fois. Les températures disponibles sont fournis ci-dessous. Une température inférieure à 98° F (37 ° C) peut être obtenue dans l'eau du robinet en mélange à...
  • Page 100: Entretien Requis

    Entretien requis L'appareil doit être inspecté chaque année par un technicien qualifié. Réparations et entretien doivent être effectuées par un technicien qualifié. Le technicien de service doit vérifier le bon fonctionnement après entre- tien. AVERTISSEMENT Pour vous protéger contre les préjudices, avant d'effectuer la maintenance : ...
  • Page 101 Nettoyez le filtre à eau Protection de gel Nettoyez le filtre à eau inlet en fermant les soupapes Assurez-vous que dans le cas de congélation météo d'isolement (fermeture) entrée froide et d'eau que le chauffe-eau et ses lignes de l'eau sont chaude.
  • Page 102: Flushing L'échangeur De Chaleur

    Un « LC » ou « 00 » code de diagnostic indique l'unité commence à chaux et doit être vidangée. Échec de vider l'appliance va causer des dommages à l'échangeur de chaleur. Dommages causés par l'accumulation de chaux ne sont pas couvert par la garantie de l'unité. Rinnai recommande fortement l'installation de vannes d'isolement pour permettre de chasse de l'échangeur de chaleur.
  • Page 103: Drainage Manuel Du Chauffe-Eau

    Drainage Manuel du chauffe-eau Pour éviter de burns, attendre jusqu'à ce que l'équipement se refroidit avant le AVERTISSEMENT drainage de l'eau. L'eau de l'appliance restera chaud après qu'il est éteint. Si le chauffe-eau ne va être utilisée pendant une période de temps au gel possible, il est recommandé que l'eau à l'intérieur du chauffe-eau être drainé.
  • Page 104 Rinnai produit standard garantie limitée, comme le prévoit le manuel d'instructions de fonctionne- ment qui est livré avec ce produit. De garantie est également disponible sur le site web de Rinnai à www.rinnai.us. APPLICATIONS RÉSIDENTIELLES: La période de garantie limitée sur la couverture du travail pour les modèles RU80 et RU98 chauffe-eau installé...
  • Page 105 Rinnai détermine la réparation d'un produit n'est pas possible, Rinnai peut remplacer le produit par un produit comparable à la seule discrétion de Rinnai. Si un composant ou un produit retourné à Rinnai est trouvé pour être exempts de défauts de matériau ou de fabrication, ou endommagé par une mauvaise installation ou endommagés pendant le transport retour, peut se voir refuser la demande de garantie pour les produits, pièces et main-d'œuvre.
  • Page 106 Limitation sur les garanties Personne n'est autorisé à apporter toute autre garantie au nom de Rinnai pour ce produit. Sauf pour ce qui est expressément communiqué ici, il n'y a aucune autre garantie, explicite ou implicite, y compris sans y être limité les garanties de valeur marchande ou d'adéquation à...
  • Page 107 U306-0661(07) 100000241(07)

Table of Contents