Rpe Sensor Removal; Bpe Sensor Removal; Hp Sensor Removal - Epson LQ-300 + Service Manual

24 pins serial impact dot matrix printer
Hide thumbs Also See for LQ-300 +:
Table of Contents

Advertisement

EPSON LQ-300+

4.2.7.5 RPE Sensor Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Remove the hook of the RPE sensor installed at the paper guide.
3.
Remove RPE sensor.
4.
Remove the harness from the RPE sensor (white).
RPE sensor (white)
Paper guide
Figure 4-16. RPE/BPE Sensor Removal

4.2.7.6 BPE Sensor Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Remove the hook of the BPE sensor installed at the paper guide.
3.
Remove BPE sensor.
4.
Remove the harness from the BPE sensor (yellow).
Disassembly and Assembly
BPE sensor (yellow)
Disassembly and Assembly

4.2.7.7 HP Sensor Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Release 2 hooks of the HP sensor securing it to the base frame with tweezers and
remove the sensor.
3.
Remove the harness from the sensor (black).
Base frame
Figure 4-17. HP Sensor Removal
Revision C
HP sensor (black)
Hook
66

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lq-305k

Table of Contents