Pg Sensor Removal; Release Lever Position Sensor Removal - Epson LQ-300 + Service Manual

24 pins serial impact dot matrix printer
Hide thumbs Also See for LQ-300 +:
Table of Contents

Advertisement

EPSON LQ-300+

4.2.7.8 PG Sensor Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Release 2 hooks of the PG sensor securing it to the left frame with tweezers and
remove the sensor.
3.
Remove the harness from the sensor (white).
Hook
Left frame
PG sensor (white)
Figure 4-18. PG Sensor Removal

4.2.7.9 Release Lever Position Sensor Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Release 2 hooks of the release lever position sensor securing it to the right frame
with tweezers and remove the sensor.
Disassembly and Assembly
3.
Remove the harness from the sensor (blue).
Release lever position sensor (blue)
Figure 4-19. Release Lever Position Sensor Removal
When installing the release lever position sensor, be sure to insert
C A U T I O N
it between the release lever and the right frame.
Disassembly and Assembly
Revision C
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lq-305k

Table of Contents