BLOWER PERFORMANCE SPECIFICATIONS
GCVM96 / ACVM96 Low Stage Cooling Speed Charts
Low-Stage Cooling Speeds
GCVM960604CX
ACVM960604CX
Cooling
Adjust
Speed Tap
Tap
Minus(-)
A
Normal
Plus (+)
Minus(-)
B
Normal
Plus (+)
Minus(-)
C
Normal
Plus (+)
Minus(-)
D
Normal
Plus (+)
* @ .1" - .8" w.c . ESP
No tes:
All furnac es ship as high speed f or c ooling. Installer must adjust blower s peed as needed.
F or most jobs , about 400 CFM per ton when c ooling is des irable.
Do not operate above .5" w. c. ESP in heat ing mode. Operating CFM between . 5" and . 8" w.c. is tabulated for cooling purposes only.
GCVM960805DX
ACVM960805DX
Cooling
CFM *
Speed Tap
333
A
370
407
486
B
540
594
711
790
C
869
882
D
980
1078
Adjust
CFM *
Tap
Minus(-)
477
Normal
530
Plus (+)
583
Minus(-)
657
Normal
730
Plus (+)
803
Minus(-)
837
Normal
930
Plus (+)
1023
Minus(-)
1098
Normal
1220
Plus (+)
1342
GCVM961005DX
ACVM961005DX
Cooling
Adjust
Speed Tap
Tap
Minus(-)
A
Normal
Plus (+)
Minus(-)
B
Normal
Plus (+)
Minus(-)
C
Normal
Plus (+)
Minus(-)
D
Normal
Plus (+)
CFM *
450
500
550
666
740
814
828
920
1012
1044
1160
1276