Goodman GCVM960604CXA Series Technical Manual page 18

40" 96% gas furnace
Table of Contents

Advertisement

BLOWER PERFORMANCE SPECIFICATIONS
GCVM96 / ACVM96 High (Single) Stage Cooling Speed Charts
High- or Single-Stage Cooling Speeds
GCVM960604CX
ACVM960604CX
Cooling
Adjust
Speed Tap
Tap
Minus(-)
A
Normal
Plus (+)
Minus(-)
B
Normal
Plus (+)
Minus(-)
C
Normal
Plus (+)
Minus(-)
D
Normal
Plus (+)
* @ .1" - .8" w.c . ESP
No tes:
All f urnac es ship as high speed f or c ooling. I nstaller must adjust blower s peed as needed.
F or most jobs , about 400 CFM per ton when c ooling is des irable.
Do not operat e above .5" w. c. ESP in heating mode. O perating CFM between . 5" and . 8" w.c. is t abulated for cooling purposes only.
18
GCVM960805DX
ACVM960805DX
Cooling
CFM *
Speed Tap
594
660
A
726
774
860
B
946
1035
1150
C
1265
1323
D
1470
1617
Adjust
CFM *
Tap
Minus(-)
810
Normal
900
Plus (+)
990
Minus(-)
990
Normal
1100
Plus (+)
1210
Minus(-)
1287
Normal
1430
Plus (+)
1573
Minus(-)
1692
Normal
1880
Plus (+)
2068
GCVM961005DX
ACVM961005DX
Cooling
Adjust
Speed Tap
Tap
Minus(-)
A
Normal
Plus (+)
Minus(-)
B
Normal
Plus (+)
Minus(-)
C
Normal
Plus (+)
Minus(-)
D
Normal
Plus (+)
CFM *
702
780
858
963
1070
1177
1242
1380
1518
1602
1780
1958