9.19 USER SETTINGS

9.19USER SETTINGS
The following pages intend to be useful to register the user settings. They can be used as a guide or template or to record
the relay settings.
PRODUCT SETUP
Relay Status
Frequency
Phase CT ratio
Ground CT ratio
HMI Password
Comm Password
Slave Address
Communications Speed
Phase TOC Function
51P Permission to Trip
51P Pickup Value
51P Curve Type
51P Time Dial
51P Definite Time Delay
Ground TOC Function
51G Permission to Trip
51G Pickup (for 1/5 A
ground)
51G Pickup (for sensitive
ground)
51G Curve Type
51G Time Dial
51G Definite Time Delay
Phase IOC High Setting
50P1 Permission to Trip
50P1 Tap / Pickup
50P1 Time Delay
Phase IOC Low Setting
9
50P2 Permission to Trip
50P2 Tap / Pickup
50P2 Time Delay
Ground IOC High Set.
50G1 Permission to Trip
50G1 Tap / Pickup (for 1/5
A ground)
9-26
ENERVISTA MII SETUP HMI
PRODUCT SETUP
PRODUCT SETUP
Relay Operation
Relay Operation
Frequency
Frequency
Phase CT Ratio
Phase CT Ratio
Ground CT Ratio
Ground CT Ratio
---
HMI Password
---
Comm Password
---
Slave Address
---
Comm Baud Rate
PHASE TOC 51P
PHASE TOC 51P
Trip Enable 51P
Trip Enable 51P
Pickup 51P
Pickup 51P
Curve 51P
Curve 51P
TD mult 51P
TD mult 51P
Def Time 51P
Def Time 51P
GROUND TOC 51G
GROUND TOC 51G
Trip Enable 51G
Trip Enable 51G
Pickup 51G
Pickup 51G
Pickup 51G
Pickup 51G
Curve 51G
Curve 51G
TD Mult 51G
TD Mult 51G
Def Time 51G
Def Time 51G
50P1 Function
Phase IOC 50P1
50P1 Trip
Trip Enable 50P1
50P1 Pickup
Pickup 50P1
50P1 Time Delay
Delay 50P1
50P2 Function
Phase IOC 50P2
50P2 Trip
Trip Enable 50P2
50P2 Pickup
Pickup 50P2
50P2 Time Delay
Delay 50P2
50G1 Function
Ground IOC 50G1
50G1 Trip
Trip Enable 50G1
50G1 Pickup
Pickup 50G1
MIFII Digital Feeder Relay
9 RELAY COMMISSIONING

9.19.1 MAIN SETTINGS

USER
RANGE
SETTING
READY / DISABLE
50/60 Hz
1-4000
1-4000
0-9999
1 – 255
1 – 255
0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2
Yes/No
0.1-2.4 In (Ph)
DEFINITE TIME, USER, MOD
INVERSE, VERY INVERSE,
EXTR INVERSE, INVERSE
LONG, INVERSE SHORT
0.05 – 2.00 (IEC curves)
0.5 – 20.0 (ANSI curves)
0.5 – 10.0 (IAC curves)
0.00 – 600.00 s.
Yes/No
0.10 – 2.40 In (Gnd)
0.005-0.12 A
DEFINITE TIME, USER, MOD
INVERSE, VERY INVERSE,
EXTR INVERSE, INVERSE
LONG, INVERSE SHORT
0.05 – 2.00 (IEC curves)
0.5 – 20.0 (ANSI curves)
0.5 – 10.0 (IAC curves)
0 –600.00s.
Yes/No
0.1 – 30.0 In (Ph)
0 – 600.00 s.
Yes/No
0.1 – 30.0 In (Ph)
0 – 600.00 s.
Yes/No
0.1 – 30 In (Gnd)
STEP
NA
NA
1
1
1
1
1
NA
NA
0.01 In (Ph)
NA
0.01
0.01
0.01
0.01 s.
NA
0.01 In
(Gnd)
0.001 A
NA
0.01
0.01
0.01
0.01 s.
NA
0.1 In (Ph)
0.01 s.
NA
0.1 In (Ph)
0.01 s.
NA
0.1 In (G)
GEK-106237P