Options and accessories

Condenser Coil and Sound Options
MCHX E-Coat
Low Sound Compressor Blankets
Value Sound Fans
Ultra-Low Sound
Controls/Communication Options
BACnet Communications
BACnet Translator Control
Chillervisor System Manager III Multi-Unit Control
Energy Management Module (EMM)
LON (Local Operating Network) Translator Control
Navigator™ Display
Remote Enhanced Display
Touch Pilot™ Display
Cooler Options
Freeze Protection — Cooler Heaters
Remote Cooler Kit
Electrical Options
Unit-Mounted Main Disconnect, Non-Fused
GFI Convenience Outlet (115 v)
High SCCR (Short Circuit Current Rating)
Hydronics Option
Hydronic Pump Package
Fluid Storage Tank
Refrigeration Circuit Options
Low Ambient Temperature Head Pressure Control
Hot Gas Bypass (not available on sizes 010 and 015)
Digital Compressor (not available on size 018)
Security/Packaging Options
Security Grilles/Hail Guards
Vibration Isolation
Wind Baffles
Factory-installed options
Novation
®
heat exchanger technology microchan-
nel coil (aluminum fin/aluminum tube) e-coat con-
denser is available for optimum durability. Novation heat
exchangers with microchannel coil technology are offered
coated or uncoated to match coil protection to site condi-
tions. The Carrier Electronic Catalog (E-Cat) can be used to
determine whether or not corrosion protection is recom-
mended for particular applications in coastal/marine envi-
ronments. Following the input of the requested data, the E-
Cat program output will advise the appropriate coil to be
used. Other factors described in "Selection Guide: Environ-
mental Corrosion Protection, Novation Heat Exchanger
with Microchannel Coil Technology" catalog number 04-
581042-01 must also be considered to determine if corro-
sion protection is required.
Value sound fans provide a metal, propeller-type fan sys-
tem which is cost-effective when compared to the low-
sound AeroAcoustic™ fan system. This factory-installed fan
option is compatible with the Motormaster
Ultra-low sound provides a combination of low sound
AeroAcoustic™ fans with sound blankets.
Digital compressor control allows incremental unload-
ing for a closer match to building load. This option is not
available on the 018 size unit.
High short circuit current rating provides a short cir-
cuit current rating protection for the unit up to 65,000 A
ITEM
®
V option.
FACTORY-INSTALLED OPTION
X
X
X
X
X
X
X
X
X
X
X
X
X
X
on 460-v, 380-v, and 208/230-v units or 25,000 A on
575-v units.
Motormaster
®
V low-ambient control provides con-
trol of fan motor operation to maintain head pressure at
low outdoor ambient temperatures down to –20 F (–29 C)
This option also requires field-installed wind baffles. This
option is also available as an accessory. This option is a
standard feature on all 30RAP010 and 015 chillers.
Non-fused disconnect includes factory-installed non-
fused disconnect capability for power and control located
at the unit.
Energy management module provides energy manage-
ment capabilities to minimize chiller energy consumption.
Several features are provided with this module including
leaving fluid temperature reset, cooling set point reset or
demand limit control from a 4 to 20 mA signal, 2-point
demand limit control (from 0 to 100%) activated by a
remote contact closure, and discrete input for "Ice Done"
indication for ice storage system interface. The EMM is
also available as an accessory.
Freeze protection with cooler heaters provides protec-
tion from cooler freeze-up to –20 F (–29 C).
GFI convenience outlet is a factory-installed conve-
nience outlet that includes 4-amp GFI (ground fault inter-
rupter) receptacle with independent fuse protection.
Convenience outlet is 115-v female receptacle. This option
is also available as an accessory.
FIELD-INSTALLED ACCESSORY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X