11 - OPTIONS AND ACCESSORIES

Options
Light-brine solution, down to
-3°C
Master/slave operation
Single power connection point
Evap. pump power/control
circuit
Evap. dual pumps power/
control circuit
Cond. pump power/control
circuit
Condenser insulation
Service valve set
Evaporator with one pass less 100C
Condenser with one pass less 102C
21 bar evaporator
21 bar condenser
Reversed evaporator water
connections
Reversed condenser water
connections
Lon gateway
Bacnet over IP
Modbus over IP and
RS485
High condensing temperature
Condensing temperature
limitation
Control for low cond.
temperature systems
Description
Implementation of new algorithms of control to
allow chilled brine solution production down to
8
-3°C when ethylene glycol is used (0°C with
propylene glycol)
Unit equipped with supplementary water outlet
temperature sensor kit to be field-installed 
58
allowing master/slave operation of two units
connected in parallel
Unit power connection via one main supply
81
connection
Unit equipped with an electrical power and
84
control circuit for one pump evaporator side
Unit equipped with an electrical power and
84D
control circuit for two pumps evaporator side
Unit equipped with an electrical power and
84R
control circuit for one pump condenser side
86
Thermal condenser insulation
Liquid line valve (evaporator inlet) and
92
compressor suction line valve
Evaporator with one pass on the water side.
Evaporator inlet and outlet on opposite sides.
Condenser with one pass on the water side.
Condenser inlet and outlet on opposite sides.
Reinforced evaporator for extension of the
104
maximum water-side service pressure to 21
bar (standard 10 bar)
Reinforced condenser for extension of the
104A
maximum water-side service pressure to 21
bar (standard 10 bar)
107 Evaporator with reversed water inlet/outlet
107A Condenser with reversed water inlet/outlet
Two-directional communication board
148D
complying with Lon Talk protocol
Two-directional high-speed communication
149
using BACnet protocol over Ethernet network
(IP)
Bi-directional high-speed communication using
149B
Modbus protocol over Ethernet network (IP)
Optimized compressor for operation at high
150
condensing temperature
Limitation of the maximum condenser leaving
150B
water temperature to 45°C
Output signal (0-10 V) to control the condenser
152
water inlet valve
Advantages
Matches with most application
requirements for ground-sourced heat
pumps and fits with many industrial 
processes requirements
Optimised operation of two units connected
in parrallele operation with operating time
equalisation
Quick and easy installation
Quick and easy installation: the control of
fixed speed pumps is embedded in the unit 
control
Quick and easy installation: the control of
fixed speed pumps is embedded in the unit 
control
Quick and easy installation: the control of
fixed speed pumps is embedded in the unit 
control
Minimizes thermal dispersions condenser
side (key option for heat pump or heat
recovery applications) and allows
compliancy with special installation criteria
(hot parts insulated)
Allow isolation of various refrigerant circuit
components for simplified service and 
maintenance
Easy to install, depending on site.
Reduced pressure drops
Easy to install, depending on site.
Reduced pressure drops
Covers applications with a high water
column evaporator side (typically high
buildings)
Covers applications with a high water
column condenser side (typically high
buildings)
Easy installation on sites with specific 
requirements
Easy installation on sites with specific 
requirements
Connects the unit by communication bus to
a building management system
Easy and high-speed connection by
ethernet line to a building management
system. Allows access to multiple unit
parameters
Easy and high-speed connection by
ethernet line to a building management
system. Allows access to multiple unit
parameters
Increased condenser leaving water
temperature up to 70°C. Allows
applications with high condensing
temperature (heat pumps, installations with
not generously sized dry-coolers or more
generally, installations with dry-coolers in
hot climate). NOTE: to ensure control of
the condenser leaving water temperature,
this option must be fitted with 30XWH 
units.
Reduced maximum power input and
current absorption: power cables and
protection elements can therefore be
downsized
Simple installation: for applications with
cold water at condenser inlet (ex. ground-
source, groundwater-source, superficial 
water-source applications) the signal
permits to control a 2 or 3-way valve to
maintain condenser water temperature
(and so condensing pressure) at
acceptable values
Use for
30XW-PZE
range
301-1101
301-1101
801-1101
301-1001
301-1001
301-1001
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101
301-1101