Adding Alternate Paths By Selecting Multiple External Lus (Add Paths); Add Paths Window - HP StorageWorks XP12000 User Manual

External storage xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

1.
Follow
step 1
2.
In the Configured Paths table, right-click the row of the path currently defined as the alternate path,
and select Delete.
The selected alternate path's definition is canceled, and detailed information about the path is deleted
from the Configured Paths table.
3.
In the Available Paths table, right-click the row of the path to be defined as the new alternate path,
and select Add.
The specified alternate path is defined, and detailed information about the path is displayed in the
Configured Paths table.
4.
Follow
step 6

Adding alternate paths by selecting multiple external LUs (Add Paths)

To add paths other than the alternate paths you set when you mapped the volume, add paths at one time
by selecting multiple external LUs belonging to the same external LU group. To do this, set the alternate
path in the Add Paths window
apply the setting to the array.
CAUTION:
After adding paths using the Add Paths window, you can change the path setting for each
external LU in the Path Setting window. However, you cannot delete all current paths to completely
interchange them with the newly added paths. At least one current path setting must remain, even if you
added new paths using the Add Paths window.
NOTE:
Use the Add Paths window to add paths to multiple external LUs at one time. However, path
settings might not be applied because of the current path setting of each volume. After setting paths in the
Add Paths window, check whether or not the new path settings can be applied in the Path Setting window
for each external LU. If the setting cannot be applied, the setting from the Add Paths window does not
appear on the Path Setting window. The setting from the Add Paths window also does not appear in the
Preset list or in the LU Operation pane.

Add Paths window

Figure 52
Port
Local array ports. After selecting a port, you can add paths.
Selected Paths
Paths that are added as ports that configure alternate paths. WWNs identify ports on the external
array. Nothing is displayed when you initially access the Add Paths window.
Unselected Paths
External array ports (WWNs) that can configure the path connecting with the local array port selected
in the Port list. Select WWNs from this list to add as alternate paths.
Set
Moves WWNs selected in Unselected Paths to Selected Paths.
to
step 3
in
"Defining alternate
to
step 8
in
"Defining alternate
(Figure
52), check the setting in the Path Setting window
paths" on page 87.
paths" on page 87.
External Storage XP user guide
(Figure
50), and
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp10000Storageworks svs200

Table of Contents