Table 13
System parameter settings (Thunder 9500V subsystems) (continued)
Pane name
Common 1
OPTION 1
OPTION 2
Data Striping
Inquiry Setting
Port Type
Controller Option
Host Connection Mode
NOTE:
When using the Thunder 9500V subsystem as an external array, the following versions are
recommended. If you use a 9500V subsystem whose version is earlier than the following versions, the
SATA drive's information might not be displayed correctly.
•
For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
•
For Thunder 9580V, Thunder 9585V: version 1658 or later
114 Notes on connecting external arrays
Parameter
Delay Planned Shutdown
SCSI Fibre Channel Common Options
SCSI Fibre Channel Common Options
Operation if the processor failure occurs
Command Queuing Mode
Vendor ID
Product ID
ROM Microprogram Version
RAM Microprogram Version
WEB Title
Reset/LIP Mode
•
Reset/LIP Mode (Signal)
•
Reset/LIP Mode (Process)
•
LIP Reset Mode
RS232C Error Information Outflow Mode
Write and verify mode
Host Connection Mode 1
Host Connection Mode 2
Parameter setting
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
Set this parameter to Reset of occurred.
Set this parameter to ON.
Keep this parameter as HITACHI (default),
and do not change.
Keep this parameter as DF600F (default),
and do not change.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
You can either specify this parameter or
omit specifying this parameter.
Set this parameter to ON.
Set this parameter to Standard Mode.
Specify HISUP Mode.
NOTE:
Do not specify any other
parameters.