60 Hz Description; Model Number Descriptions - Trane Voyager Commercial Installation & Operation Manual

Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant
Hide thumbs Also See for Voyager Commercial:
Table of Contents

Advertisement

Model Number Descriptions

60 Hz Description

Digit 1, 2 — Unit Function
TC =
DX Cooling, No Heat
TE =
DX Cooling, Electric Heat
YC =
DX Cooling, Natural Gas Heat
Digit 3 — Unit Airflow Design
D
=
Downflow Configuration
H
=
Horizontal Configuration
Digit 4, 5, 6 — Nominal Cooling
Capacity
330 =
27½ Tons
360 =
30 Tons
420 =
35 Tons
480 =
40 Tons
600 =
50 Tons
Digit 7 — Major Development
Sequence
B
=
R-410A Refrigerant
Digit 8 — Power Supply
E
=
208/60/3
F
=
230/60/3
4
=
460/60/3
5
=
575/60/3
Digit 9 — Heating Capacity
0
=
No Heat (TC only)
L
=
Low Heat (YC only)
H
=
High Heat (YC only)
J
=
Low Heat-Stainless Steel Gas
Heat Exchanger (YC only)
K
=
High Heat-Stainless Steel Gas
Heat Exchangers (YC only)
M =
Low Heat-Stainless Steel Gas
Heat Exchanger w/
Modulating control
(27.5-35 ton YC only)
P
=
High Heat-Stainless Steel Gas
Heat Exchangers w/
Modulating control
(27.5-35 ton YC only)
R
=
Low Heat-Stainless Steel Gas
Heat Exchanger w/
Modulating control
(40-50 ton YC only)
T
=
High Heat-Stainless Steel Gas
Heat Exchangers w/
Modulating control
(40-50 ton YC only)
Note: When second digit is "E" for
Electric Heat, the following values
apply in the ninth digit.
A
=
36 kW (27 kW for 208v)
B
=
54 kW (41 kW for 208v)
C
=
72 kW
D
=
90 kW
E
=
108 kW
Digit 10 — Design Sequence
A
= First
8
Digit 11 — Exhaust
0
=
None
1
=
Barometric Relief (Available
w/ Economizer only)
2
=
100% Power Exhaust Fan
(Available w/ Economizer only)
3
=
50% Power Exhaust Fan
(Available w/ Economizer only)
4
=
100% Fresh Air Tracking Power
Exhaust Fan (Available
w/ Economizer only)
5
=
50% Fresh Air Tracking Power
Exhaust Fan (Available
w/ Economizer only)
6
=
100% Power Exhaust w/
Statitrac™
Digit 12 — Filter
A
=
2" Std Eff, Throwaway Filters
B
=
2" MERV 8, High Eff, Throwaway
Filters
C
=
4" MERV 8, High Eff, Throwaway
Filters
1
D
=
4" MERV 14, High Eff, Throwaway
Filters
Digit 13 — Supply Fan Motor, HP
1
=
7.5 Hp
2
=
10 Hp
4
3
=
15 Hp
4
=
20 Hp
Digit 14 — Supply Air Fan Drive
Selections
A
=
550 RPM
B
=
600 RPM
C
=
650 RPM
D
=
700 RPM
E
=
750 RPM
F
=
790 RPM
G
=
800 RPM
Digit 15 — Fresh Air Selection
A
=
No Fresh Air
B
=
0-25% Manual Damper
C
=
0-100% Economizer, Dry Bulb
Control
D
=
0-100% Economizer,
Reference Enthalpy Control
E
=
0-100% Economizer,
Differential Enthalpy Control
F
=
"C" Option and Low Leak
FreshAir Damper
G
=
"D" Option and Low Leak
Fresh Air Damper
H
=
"E" Option and Low Leak
Fresh Air Damper
Digit 16 — System Control
1
=
Constant Volume
2
=
VAV Supply Air Temperature
Control w/o Inlet Guide Vanes
3
=
VAV Supply Air Temperature
Control w/Inlet Guide Vanes
4
=
VAV Supply Air Temperature
6
3
H
=
500 RPM
J
=
525 RPM
K
=
575 RPM
L
=
625 RPM
M =
675 RPM
N =
725 RPM
Control w/Variable Frequency
Drive w/o Bypass
5
=
VAV Supply Air Temperature
Control w/Variable Frequency
Drive and Bypass
Note: Zone sensors are not included
with option and must be ordered
as a separate accessory.
Miscellaneous Options
Digit 17
2
A
=
Service Valves
Digit 18
B
=
Through the Base Electrical
Provision
Digit 19
C
=
Non-Fused Disconnect Switch
with External Handle
Digit 20
D
=
Factory-Powered 15A GFI
Convenience Outlet and
Non-Fused Disconnect Switch
with External Handle
Digit 21
E
=
Field-Powered 15A GFI
Convenience Outlet
Digit 22
F
=
Trane Communication
Interface (TCI)
Digit 23
G
=
Ventilation Override
Digit 24
H
=
Hinged Service Access
Digit 25
H
=
Tool-less Condenser Hail Guards
J
=
Condenser Coil Guards
Digit 26
K
=
LCI (LonTalk)
B
=
BACnet Communications
Interface (BCI)
Digit 27
*
=
Unused Digit
Digit 28
M =
Stainless Steel Drain Pans
Digit 29 — Condenser Coil
Options
0
=
Standard Efficiency
Condenser Coil
N
=
Standard Efficiency
Condenser Coil with Black
Epoxy Pre-Coating
Digit 30-31 — Miscellaneous
Options
RT-SVX34C-EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents