b. Paper remaining quantity detector
1)
Remove the paper feed tray.
(See "(1) Paper feed unit (Paper feed tray 3, 4)")
2)
Disconnect the connecter, and remove the paper remaining
quantity detector unit.
3)
Remove the paper remaining quantity detector cover. Remove
the paper remaining quantity detector.
c. Paper feed tray paper width detector
1)
Remove the paper feed tray 3, 4 unit lower.
(See "(1) Paper feed unit (Paper feed tray 3, 4)")
2)
Disconnect the connector, and release the pawl, and remove
the width detection unit.
3)
Remove the spring, and remove the paper width mounting
base. Remove the width detection arm and remove the paper
feed tray paper width detector.
MX-M700N TRAY PAPER FEED SECTION F – 16
d. Dry heater
1)
Remove the paper feed tray 3, 4 unit lower.
(See "(1) Paper feed unit (Paper feed tray 3, 4)")
2)
Remove the paper feed lower cover.
3)
Remove the rear cabinet.
4)
Disconnect the connector from the dehumidifying heater relay
PWB.
5)
Remove the snap band.