Infinity Model
Installation
G20 Nat Gas Press Low
G20 Nat Gas Press High
G25 Nat Gas Press Low
G25 Nat Gas Press High
G31 Propane / G30 Butane Press Low
G31 Propane / G30 Butane Press High
Flue System
Temp. Range Controllers
Temp. via dip switches
Ignition
Gas Consumption & Capacities min conditions
G20 Nat Gas: Input Q
Hi/Hs | Useful output P
m:
G20 Nat Gas flow V
G25 Nat Gas: Input Q
: Hi/Hs | Useful output P
m
G25 Nat Gas flow ref. conditions V
G30 Input Q
: Hi/Hs | Useful output P
m
G30 flow normal operating conditions M
G31 Input Q
: Hi/Hs | Useful output P
m
G31 flow normal operating conditions M
Gas Consumption & Capacities nominal condit.
G20 Nat Gas: Input Q
: Hi/Hs | Useful output P
n
G20 Nat Gas flow ref. conditions V
G25 Nat Gas: Input Q
: Hi/Hs | Useful output P
n
G25 Nat Gas flow ref. conditions V
G30 Input Q
: Hi/Hs | Useful output P
n
G30 flow normal operating conditions M
G31 Input Q
: Hi/Hs | Useful output P
n
G31 flow normal operating conditions M
Country of destination
Gas category and pressure
Type
Max Flow ( delta T = 21° K )
Min Operation Flow
Water Pressure (P
)
w
Power Supply
Electric Consumption (1 remote)
Noise Level
Ignition safety time T
SAmax
* Minimum operation pressure and flow based on temperature setpoint and inlet conditions.

TECHNICAL DETAILS

Inf. Cond.32e/HDC1500e
Direct Forced Exhaust
37-46,48,50,55 - Infinity Range (plus 60,65,75 - HDC)
H
= net calorific value H
i
2.55/2.83 | 2.27
m
2.55/2.83 | 2.27
m
r
3.17/3.44 | 2.75
m
m
2.78/3.02 | 2.42
m
m
H
= net calorific value H
i
53.6/59.5 | 56
n
r
53.6/59.5 | 56
n
r
61.7/67.06 | 62.2
n
n
54.1/58.8 | 54.7
n
n
I
G20-20mbar / I
2H
A3 Outdoor
42
Inf. Cond.32i/HDC1500i
External
1.81
5.64
2.35
7.40
2.65
7.99
Forced, Room Sealed
40, 42, 50, 55, 60, 65, 75, 85
Direct Electronic Ignition
= gross calorific value
s
2.55/2.83 | 2.27
0.27
2.55/2.83 | 2.27
0.31
3.17/3.44 | 2.75
0.25
2.78/3.02 | 2.42
0.22
= gross calorific value
s
53.6/59.5 | 56
5.7
53.6/59.5 | 56
6.6
61.7/67.06 | 62.2
4.87
54.1/58.8 | 54.7
4.2
GB/IE
G25-25mbar / I
2L
37
1.5*
1.0* - 10.0 (recommend 2.0 min.)
230 V / 50 Hz
72
50
4.2
Units
Internal
2.26
mbar
6.28
mbar
2.81
mbar
8.00
mbar
3.19
mbar
9.02
mbar
deg C
deg C
kW
3
0.27
m
/hr
kW
3
0.31
m
/hr
kW
0.25
Kg./hr
kW
0.22
Kg./hr
kW
3
5.7
m
/hr
kW
3
6.6
m
/hr
kW
4.87
Kg./hr
kW
4.2
Kg./hr
G31-37mbar
3P
C13/33
37
L/min
1.5*
L/min
bar
99
Watts
dB (A)
Sec.