RESTARTING THE RINNAI WATER HEATER

The heaters should be restarted in this manner.
Standard system.
Single or multiple water heaters without remote controllers.
The heaters will automatically reset without any user involvement.
Single or multiple water heaters with remote controllers.
The heaters will be required to be switched on using the ON/OFF button on a remote
controller. Ensure that all taps/water outlets are closed and no water is flowing through
heaters.
Hot water system incorporating secondary recirculation pump.
Single or multiple water heaters without remote controllers.
The heater(s) will automatically reset without any user involvement.
Single or multiple water heater(s) with remote controller(s).
To reset the heaters follow the steps.
1. Turn off all hot water taps.
2. Turn off supply to secondary circulating pump or alternatively, isolate pump flow.
3. Turn on heater at remote control.
4. Select required temperature.
5. Switch on supply to secondary circulating pump or open valve on pump flow.
The heater will now be ready to supply water at the set temperature.
If following the above procedure does not reset the heater switch it on and off at its main
supply, and then go through these steps again. If heater is still not working call your local
service agent or Rinnai for assistance.

CARING FOR THE INFINITY

Maintenance
Even if there does not seem to be a problem with the water heater it is required in the UK
that all gas appliances are serviced every year by a certified gas engineer. This is to ensure
continued safety of the gas appliance. If you need a recommended service engineer contact
Rinnai or your supplier.
Care
When the appliance casing, operation panel, and remote controls surfaces become dirty
gently wipe them clean with a soft, damp cloth. Do not use detergents on these parts.
Filter
The water heater has a filter on the cold water inlet connection. This filter will need to be
cleaned occasionally. How often will be determined by the local water conditions. The water
filter can be located on the diagram on page 20. Isolate the cold water inlet and hot water
outlet with the valves near the heater. Release the pressure in the heater by unscrewing the
drain valve (shown on page 20.) Then remove the filter, clean it and replace it.