Measuring The Dc Voltages (Test Points) - Tektronix Phaser 740 Service Manual

Hide thumbs Also See for Phaser 740:
Table of Contents

Advertisement

DC Output: With the VOM set to measure DC voltages, measure voltages at CN301
for +5 VDC and +24 VDC. If the voltage is not correct, replace the power supply. The
following illustration shows the test points.
Power supply
CN 301
Pin 9 - +24 V
Pin 8 - GND
Pin 7 - GND
Pin 6 - GND
Pin 5 - +24 V
Pin 4 - +24 V
Pin 3 - GND
Pin 2 - +5 V
Pin 1 - +5 V

Measuring the DC voltages (test points)

If DC voltages are not being output by the power supply, proceed to the next step,
"Inspecting the power supply fuses" on page 41.
If the +5 and +24 VDC voltages measure correctly, but the printer does not operate
correctly, then proceed to the topic, "Safety interlocks" on page 41.
40
Phaser 740 and 750 Color Printers
1
9
3102-06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 750

Table of Contents