Mitsubishi Electric FR-F700 Series Instruction Manual page 56

Fr-f700 series
Hide thumbs Also See for FR-F700 Series:
Table of Contents

Advertisement

Parameter
Name
Number
0
Torque boost
Maximum
1
frequency
Minimum
2
frequency
3
Base frequency
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal
9
O/L relay
Energy saving
60
control selection
Operation mode
79
selection
Terminal 2
125
frequency setting
gain frequency
Terminal 4
126
frequency setting
gain frequency
User group read
160
selection
Incre
Initial
Range
ments
Value
6/4/3/2/
0.1%
0 to 30%
1.5/1%
*1
120/
0.01Hz
0 to 120Hz
60Hz
*2
0.01Hz
0Hz
0 to 120Hz
0.01Hz
60Hz
0 to 400Hz
0.01Hz
60Hz
0 to 400Hz
0.01Hz
30Hz
0 to 400Hz
0.01Hz
10Hz
0 to 400Hz
0.1s
5/15s
0 to 3600s
*3
0.1s
10/30s
0 to 3600s
*3
Rated
0.01/
inverter
0 to 500/
0.1A
output
0 to 3600A
*4
current
1
0
0, 4, 9
1
0
0, 1, 2, 3, 4, 6, 7
0.01Hz
60Hz
0 to 400Hz
0.01Hz
60Hz
0 to 400Hz
1
0
0, 1, 9999
Simple mode parameter list
Applications
Set to increase a starting torque or when the
motor with a load will not rotate, resulting in
an alarm [OL] and a trip [OC1]
*1
Initial values differ according to the inverter
capacity.
Inverter capacity
200V class
400V class
00046
00023
00077 to 00167
00038 to 00083
00250, 00340
00126, 00170
00490 to 01540
00250 to 00770
01870 or more
00930, 01160
-
01800 or more
Set when the maximum and minimum
output frequency need to be limited.
*2
Initial values differ according to the inverter
capacity. (200V class and FR-F740-01160 or
less/ FR-F740-01800 or more)
Set when the rated motor frequency is 50Hz.
Check the motor rating plate.
Set when changing the preset speed in the
parameter with a terminal.
Acceleration/deceleration time can be set.
*3
Initial values differ according to the inverter
capacity. (FR-F720-00340 or less/FR-F720-
00490 or more, FR-F740-00170 or less/FR-
F740-00250 or more)
Protect the motor from overheat by the
inverter.
Set the rated motor current.
*4
Setting increments and setting range differ
*4
according to the inverter capacity.
(200V class and FR-F740-01160 or less/ FR-
F740-01800 or more)
The inverter output voltage is minimized
when using for fan and pump applications.
Select the operation command location and
frequency command location.
Frequency for the maximum value of the
potentiometer (at 5V) can be changed.
Frequency at 20mA input can be changed.
Make extended parameters invalid
Refer
to
Initial
value
52
6%
4%
3%
2%
1.5%
1%
53
33
44
54
32
55
57
47
4
49
102
51