KSTDV Series Gas Fireplace
electrical Grounding Instructions: This
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
The black and white wires on the ac box
wiring harness are marked 'Blower', 'light'
and 'aux'. It is important to use the wires
marked 'Blower' or the control will not work
correctly.
BloTKSTSc SIGnaTure coMManD Blower
To Junction Box
In Fireplace
Blower (300w Max)
The BLOTKSTSC Blower Kit requires the SCSACM A/C
Module and the TSFRSC remote to install and operate
this kit. Refer to blower instructions for installation and
remote instructions for operation.
26
{
Light
WHITE
BLACK
WHITE
BLACK
{
BLACK
Optional
WHITE
AUX
Figure 32 -
BLOTKSTSC Blower Wiring Diagram
FP2708
BLOTKSTSC fan wiring
opTIonal Fan Blower SySTeM
electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
GREEN
Connector
Pin To Contro l Box
control Box
ac Module
FP2708
73D4125