Economy control switch

1 "I" (ON)
When the economy control switch is turned "I" (ON),
the economy control unit controls the engine speed
according to the connected load. The results are bet-
763-124a
ter fuel consumption and less noise.
2 "3" (OFF)
When the economy control switch is turned "3" (OFF),
the engine runs at the rated r/min (3,600 r/min)
regardless of whether there is a load connected or
not.
TIP
The economy control switch must be turned to "3"
(OFF) when using electric devices that require a large
starting current, such as a compressor or a submers-
ible pump.
AE00780

DC protector

The DC protector turns off automatically when electric
device being connected to the generator is operating
and current above the rated flows. To use this equip-
ment again, turn on the DC protector by pressing its
button to
763-188a
"I" (RESET)
1
Direct current is output. (This is the default position.)
2
"3" (OFF)
2
1
Direct current is not output.
763-006
NOTICE
Reduce the load of the connected electric device
below the specified rated output of the generator
if the DC protector turns off. If the DC protector
turns off again, stop using the device immediately
and consult a Kohler portable dealer.