DC Inverter Floor Ceiling Type Air Conditioner Installation and Operation Manual
Selection of Installation Location
① Such a place where cool air can be distributed throughout the room.
② Such a place where condensation water is easily drained out.
③ Such a place that can handle the weight of indoor unit.
④ Such a place which has easy access for maintenance.
⑤ Such a place where is easy to connect the outdoor unit.
⑥ Such a place which is 1m or more away from other electric appliances such as television, audio device,
etc.
⑦ Avoid a location where there is heat source, high humidity or inflammable gas.
⑧ Do not use the unit in the immediate surroundings of a laundry, a bath, a shower or a swimming pool.
⑨ Ensure that the installation conforms to the installation dimension diagram.
⑩ A space around the unit is adequate for ventilation (See Fig.41)
There are two types of installation: Ceiling Type and Floor Type
Each type is similar to the other as follows:
Determine the mounting position on the ceiling or the wall by using the paper pattern to indicate the indoor
frame. Mark the pattern and pull out the paper pattern. Remove the return grill, the side panel and the hanger
bracket from the indoor unit as per procedures below.
① Press the fixing knob of the return grilles and Loosen fixing bolts (M4.2). It will be opened widely, and
then pull it out from the indoor unit.(See Fig.41)
② Remove the side panel fixing screws and remove it away by pulling it out at the front direction (arrow
direction). (See Fig.42)
③ Loosen two hanger bracket setting bolts (M10) on earth side for less than 10mm. Remove two hanger
bracket fixing bolts (M6) on the rear side. Detach the hanger bracket by pulling it backward (See Fig.44)
Fig. 41
Fig. 42
43